background image

 

  

Installation 

The descriptions below apply to general door specifications. The specifications of the door 
manufacturer must also be observed during installation. 
 
 

Warning - Potential injury or danger to life! 

 

 

During installation, be sure to use a lifting device that has a sufficient load-
carrying capacity. 

 

 

Thoroughly grease the door shaft. 

 

BAGAE01001_Z003

 

 

 

Mount the keys. 

 

 

BAGAE03002_Z001

 

 

Содержание 10002363 10011

Страница 1: ... Deckblatt BAAA000001_M003 17 mod_1444211755814_28 docx 891110 1 Installation Instructions ELEKTROMAT SI 25 10 30 00 Model 10002363 10011 en Status 06 03 2020 Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 2: ...t BACA000001_M002 15 mod_1416821436083_28 docx 864410 1 GfA ELEKTROMATEN GmbH Co KG Wiesenstraße 81 D 40549 Düsseldorf www gfa elektromaten de info gfa elektromaten de Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 3: ...8 Limit switch connection 13 9 Emergency manual operation emergency hand crank 14 10 Completion of commissioning testing 16 11 Declaration of incorporation Declaration of conformity 18 Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 Symbols Warning Potential injury or danger to life Warning Danger to life from electric current Note Important information Requirement Required ac...

Страница 4: ...nt of the manufacturer Otherwise the Manufacturer s Declaration shall be rendered null and void Safety information Installation and initial operation tasks are to be performed by trained skilled fitters only Only trained electrical craftsmen are permitted to work on electrical equipment They must assess the tasks assigned to them recognise potential danger zones and be able to take appropriate saf...

Страница 5: ...peration 18 15 rpm Supply voltage 3N 400 V Operating current 1 80 A Operating frequency 50 Hz Power factor cos φ 0 67 Maximum movement per hour 20 h 1 Hand forces 85 N Class of protection IP 65 Limit switch range maximum revolutions of output shaft hollow shaft 20 Temperature range 10 40 60 C Pos null BA_Module BA_FC Temperaturbereich BAFC000001_M002 23 mod_1508937126225_28 docx 1055098 1 1 When u...

Страница 6: ...ansmission elements must not be exceeded even for maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter to the full Use adequately dimensioned washers for elongated holes BAGAB00002_Z002 BAGAB00003_Z002 3 1 Permissible mounting positions BAGAC03001_Z002 ...

Страница 7: ...7 Mounting Two elongated holes are provided for mounting BAGAD03001_Z003 ...

Страница 8: ...ions of the door manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thoroughly grease the door shaft BAGAE01001_Z003 Mount the keys BAGAE03002_Z001 ...

Страница 9: ...ghten all connection elements M12 to 75 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE03010_Z002 75 Nm 8 8 8 8 8 8 8 8 Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 10: ...he cables are de energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the limit switch plug BAHAA03_Z001 BAHAC07_Z001 Completing the electrical installation Mount the cable entries and or cable glands Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0...

Страница 11: ...111_M001 0 mod_1194954682399_28 docx 2518 1 1 5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 12: ...cx 570 1 1 6 Motor connection M1 Motor X13 Motor plug Pos null BA_Module BA_MC Alternativer Motoranschluss BAMC011001_M001 0 mod_1271681105421_28 docx 518476 1 1 7 Alternative motor connection M1 Motor X13 Motor plug Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 13: ...126757070_28 docx 963 1 1 8 Limit switch connection F10 Thermal contact S10 Manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply network Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 14: ...Adopt a secure position For drive units with brake the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 DIN EN 12453 to move the door by emergency manual operation this indicates a stalling on the drive unit or door Releasing the stalling may cause the d...

Страница 15: ...he crank and turn until it engages Open or close by turning the crank After use the crank may be attached to the drive unit Attach as illustrated Pos null BA_Module BA_Seitenumbruch 0 mod_1190719383361_0 docx 550 1 ...

Страница 16: ...safety brake is triggered to prevent the door from dropping The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling Do not use the emergency manual operation Secure the door against dropping Please observe the specifications of the door manufacturer The drive unit needs replacement Please observe the specification...

Страница 17: ...s Limit switches Check the final limit positions by opening and closing the door completely The safety zone must not be reached Entire drive unit Note Have the drive checked annually by a specialist Shorter inspection interval for frequently used doors Observe the applicable regulations and standards Ende der Liste für Textmarke Inhalt ...

Страница 18: ...talled complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned Düsseldorf 10 08 2018 Stephan Kleine CEO Signature The following requirements from Appendix I of the Machinery Directive 2006 42 EC are met 1 1 2 1 1 3 1 1 5 1 2 2 1 2 3 1 2 6 1 3 2 1 3 3 1 3 9 1 5 1 1 5 2 1 5 4 1 5 6 1 5 7 1 5 8 1 5 9 1 5 10 1 5 11 ...

Страница 19: ...19 ...

Страница 20: ...20 Ende der Liste für Textmarke Inhalt1 ...

Отзывы: