background image

 

12 

 

5

 

Electrical installation 

 

Warning - Danger to life from electric current! 

 

 

Switch the mains OFF and check that the cables are de-energised 

 

Observe the applicable regulations and standards 

 

Make a proper electrical connection 

 

Use suitable tools 

 
Performing electrical installation 

Remove the cover. 

Insert the motor plug. 

Insert the limit switch plug. 

BAHEA02_Z001

BAHEB01_Z001

BAHEC01_Z001

 
Completing the electrical installation 

Mount the cable entries and/or cable glands. 

 

 

Содержание 10003840 10011

Страница 1: ...f Installation Instructions ELEKTROMAT SI 20 100 FU 40 00 Model 10004227 10011 en Status 26 03 2021...

Страница 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Страница 3: ...switch connection 14 9 Emergency manual operation emergency hand crank 15 10 Completion of commissioning testing 17 11 Declaration of incorporation Declaration of conformity 20 Symbols Warning Potenti...

Страница 4: ...ng of door systems Expert knowledge relevant skills and practical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance a...

Страница 5: ...third parties Warning Danger from improper use of the product Do not let children operate the product unsupervised or use as a toy Warning Danger to life from incorrect installation Work carried out i...

Страница 6: ...nt 7 30 A Operating frequency 50 60 Hz Power factor cos 0 63 Maximum movement per hour 52 h 1 Hand forces 203 N Class of protection IP 65 Limit switch range maximum revolutions of output shaft hollow...

Страница 7: ...cking torque and the approval number of the safety brake are available in the technical data of these instructions Warning Danger of the door dropping If you need to apply more than the permissible fo...

Страница 8: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Страница 9: ...9 Mounting Two elongated holes are provided for mounting BAGAD03001_Z003...

Страница 10: ...ons of the door manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carryin...

Страница 11: ...the drive unit BAGAE03005_Z002 Tighten all connection elements M12 to 75 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE03010_Z002 75 Nm 8 8 8...

Страница 12: ...ised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the limit...

Страница 13: ...13 6 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Страница 14: ...1 S10 1 4 6 3 5 2 3 4 1 2 5 6 A B RS 485 A D MC 21 22 23 24 25 26 4 1 3 6 X12 W3 ws br gn ge gr rsl 1 4 6 3 5 2 4 3 6 5 2 1 S10 Emergency manual operation X12 DES connection 1 Safety circuit 2 Channel...

Страница 15: ...the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 D...

Страница 16: ...and crank be used A wrong crank will drop out of the mounting and injure people Only use a crank with the correct diameter The diameter is indicated on the crank handle switch 1 2 m m 1 0 m m BAUA0001...

Страница 17: ...g The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling Do not use the emergency manual operation Secure the door...

Страница 18: ...its equipment The manufacturer s specifications must be observed The brake release for doors without counter balancing may only be used in the CLOSE final limit position Warning Injury or danger to li...

Страница 19: ...19 Entire drive unit Note Have the drive checked annually by a specialist Shorter inspection interval for frequently used doors Observe the applicable regulations and standards...