Weld334m - User’s manual
15
3.
Power supply and 24V for I/O
3.1
Control device power supply
The power supply section resides on the PS 8way, 5.08mm pitch connector for
disconnectable terminals which are located on the front. Also housed on this connector is
the input for the external synchronism.
Either incoming direct current or alternated current is accepted by the control device (see
characteristics at paragraph 2.4).
The control device earthing is to be carried out by means of the faston terminal located at
the side of PS connector.
3.1.1
PS . Description of signals
8-way, 5.08mm pitch PS connector for disconnectable terminals
Pin
Signal
Description
1-2
PWR/RTN
Main power supply of the control device.
The device can be powered from either d.c. mains – from 18
to 36Vdc – and a.c. mains – from 14,4 to 32,4Vac – with no
need for the user to change the connections or the internal
settings.
If powered from a d.c. source, the pin polarity is irrespective
of this status.
NOTE: if the unit is fed from a d.c. supply, the external
synchronism must be used.
3-4
SYNC +/-
External synch signal.
Sensitivity: 12-33Vac.
It permits the synchronisation with power supply on the
power side (SCR), through an insulation transformer
connected to the same phase.
This must be used when the unit is powered from a line
separate than that of the welding machine or when it is
powered from the d.c. mains.
If used, this signal must be configured on the power feeder
card through 2 jumpers (see paragraph 3.4).
5
24VI
+24Vdc output, internal.
It is used when one wants to use +24V supply internal to the
device for powering the I/O.
It can be cut out for enabling 24V from a remote unit
(Robot).
For the connection, refer to paragraph 3.2.2 figure (b).
6
24VE
24Vdc external input for discrete, digital I/O.
Max. Load 1,5A.
For the connection, refer to paragraph 3.2.2 figures (c) and
(d).
7
0V
Input for 0V external common for logic I/O.
For the connection, refer to paragraph 3.2.2 figures (c) and
(d).
8
Contact available for Earth connection.
For the connection, refer to paragraph 3.2.2
Содержание Weld334m
Страница 1: ...USER S MANUAL Weld334m HC HCM HIC HIM Ed 5 December 2004 Doc 39000326...
Страница 6: ...Weld334m User s manual VI WHITE PAGE...
Страница 14: ...Weld334m User s manual 8 WHITE PAGE...
Страница 28: ...Weld334m User s manual 22 WHITE PAGE...
Страница 30: ...Weld334m User s manual F351 BUS Interconnection card 24 WHITE PAGE...
Страница 36: ...Weld334m User s manual F353 ADC Analogue Card 30 WHITE PAGE...
Страница 40: ...Weld334m User s manual F364 SEV and F385 SEV Proportional Servovalve Modules 34 WHITE PAGE...
Страница 42: ...Weld334m User s manual F359 MCP Memory Card and Printer 36 WHITE PAGE...
Страница 54: ...Weld334m User s manual F356 IOE I O Expansion Card 48 WHITE PAGE...
Страница 58: ...Weld334m User s manual F376 OPC Field Bus InterBus S Card 52 Card layout...
Страница 61: ...Weld334m User s manual F386 Ethernet 100Base T and CANbus module 55 Card layout...
Страница 62: ...Weld334m User s manual F386 Ethernet 100Base T and CANbus module 56 WHITE PAGE...
Страница 64: ...Weld334m User s manual F383 COM RS422 Serial communication card 58 Card layout...
Страница 73: ...Weld334m User s manual 67 APPENDIX...
Страница 74: ...Weld334m User s manual 68...
Страница 90: ...Weld334m User s manual 84 WHITE PAGE...
Страница 92: ......
Страница 93: ......
Страница 94: ......