Ordering Information

Mfr. Part No

Code

Description

3-9950-1-1

159 001 889

9950 Conductivity Transmitter, DC Power 

3-9950-2-1

159 001 890

9950 Conductivity Transmitter, AC Power 

3-9950-1-2

159 001 891

9950 Dual Conductivity Transmitter, DC Power

3-9950-2-2

159 001 892

9950 Dual Conductivity Transmitter, AC Power

Optional Modules and Accessories

3-9950.394-1

159 001 846

Single Channel Direct Conductivity/Resistivity Module

3-9950.393-1

159 310 268

Relay Module with 4 Mechanical Relays

3-9950.393-2

159 310 269

Relay Module with 2 Mechanical and 2 Solid State Relays

3-9950.393-3

159 310 270

Relay Module with 2 Mechanical Relays and 4 Binary Inputs

3-9900.398-2

159 001 848

Dual Channel 4 to 20 mA Current Loop Output Module

9950 Transmitter Base Unit: 
Dual Channel, Multi-Parameter, AC Power and DC Power

Содержание Signet 9950

Страница 1: ...e following modules Direct Single Channel Conductivity Resistivity Module Dual Channel Conductivity Resistivity Module Four Channel Mechanical Relay Module Optional Two Mechanical and Two Solid State...

Страница 2: ...Warranty Information Product Registration Safety Information Standards and Approvals CE UL CUL WEEE RoHS Compliant Manufactured under ISO 9001 for Quality ISO 14001 for Environmental Management and OH...

Страница 3: ...t arcing sufficient to damage the relays The RC Filter Kit or snubber part number 3 8050 396 is available as an accessory to reduce or eliminate these damaging effects Recommended for inductive loads...

Страница 4: ...mounted using the provided quick clip mounting bracket Install plug in modules first with power disconnected Next step Wiring Step 2 panel V FREQ DATA GND V FREQ DATA GND Loop1 Loop1 Loop2 Loop2 PWR P...

Страница 5: ...to eliminate fraying Insert wire tip or ferrule completely into the terminal and secure with the screw Do not allow any AC leads that may be connected to the internal relays to come in contact with l...

Страница 6: ...r Terminal 3 9950 1 or 3 9950 2 Required by the instrument 12 to 32 VDC 10 regulated 0 5 A MAX DC power input and Loop current regulated voltage require the use of a UL60950 1 or UL61010 1 certified p...

Страница 7: ...D TEMP SIGNAL SHLD 2819 2820 2821 Sanitary Tri clamp 2822 2839 2842 2839 2842 In case of noise interference connect the cable shield to earth ground Conductivity sensors connected to the Direct Conduc...

Страница 8: ...1 high 6 0 mA at 30 VDC 4 8 mA at 24 VDC 2 4 mA at 12 VDC 1 0 mA at 5 VDC Terminals accept 12 to 24 AWG wire Strip 10 to 12 mm 0 4 to 0 5 in of insulation from wire tips and tin bare ends to eliminate...

Страница 9: ...3 9950 1 MUST BE POWERED BY 12 32 VDC at 0 5 A V FREQ DATA GND V FREQ DATA GND Loop1 Loop1 Loop2 Loop2 PWR PWR CH2 CH1 DC POWER and imported par Black Red Power Supply 12 to 32 VDC Red Black PLC or R...

Страница 10: ...its of Measure GPM pH sec etc Numeric Values or labels Bar Graph Channel 2 display area Numeric Values or labels Units of Measure GPM pH sec etc Password Overview The password is required to start edi...

Страница 11: ...MM DD YYYY date format and or to scroll through other format options Press ENTER to save the date format selection 5 Press to move to the next selection SET DATE Press to scroll through the days mont...

Страница 12: ...159 001 890 9950 Conductivity Transmitter AC Power 3 9950 1 2 159 001 891 9950 Dual Conductivity Transmitter DC Power 3 9950 2 2 159 001 892 9950 Dual Conductivity Transmitter AC Power Optional Modul...

Отзывы: