Signet 9950 Conductivity Transmiter 

ENTER

4

DATE FORMAT

100% SOLUTION

NAME

SAVING

24 HOUR

AM/PM

GERMAN
LANGUAGE
LANGUAGE

00:00:04

0

AM/PM

09:11:04

MM/DD/YYYY

DD/MM/YYYY
YYYY/MM/DD

LANGUAGE
LANGUAGE

02/25/2016

2

AM/PM

02/25/2016

99.999

99,999

OR

ENTER

saves
changes

ENTER

METRIC

U.S. CUSTOMARY

LOOKING FOR 

TEXT 3

SENSOR TYPE

MM/DD/YYYY

YYYY/MM/DD

DD/MM/YYYY

NONE

FLOW

pH
ORP

FACTORY

ENTER

saves
changes

TIME FORMAT

TEXT 3

24 HOUR

SET TIME

TEXT 3

08:56:47

DATE FORMAT

TEXT 3

MM/DD/YYYY

SET DATE

TEXT 3

02/25/2016

SET DECIMAL MARK

TEXT 3

999.99

SELECT UNITS

TEXT 3

U.S. CUSTOMARY

SETUP 

3

CHANNEL 1

PRESS ENTER

SETUP 

CHANNEL 2

PRESS ENTER

 

EXIT STARTUP

PRESS ENTER

ENGLISH

DEUTCH

ESPAÑOL

中文

FRANÇ

Easy Set Up can be 
entered by setting 
either or both channels 
to Factory and cycling 
power on the 9950.

This menu operation sets up the 9950 for basic function:

1.  Select desired language using the [UP] and [DOWN] arrows.

Press ENTER to save.

2. Press 

 to select the TIME FORMAT. 

Press 

 or 

 to select 24 hour or AM/PM.  

Press ENTER to save the format selection.

3. Press 

the 

 move to the next selection, SET TIME. 

Press 

 to scroll through hours, and minutes place values. 

Use 

 or 

 to adjust the value.  

Press ENTER to save the time selection. 

4. Press 

 to move to the next selection, SET DATE FORMAT. 

Press 

 to select the MM/DD/YYYY date format and 

 or 

 

to scroll through other format options.
Press ENTER to save the date format selection. 

5. Press 

 to move to the next selection, SET DATE.  

Press 

 to scroll through the days, months, and years.

Use 

 or 

 to adjust the number, and 

 to select the next 

number.
Press ENTER to save the Date selection. 

6. Press 

 to move to the next selection, 

SET DECIMAL MARK.  
Press 

 and use 

 or 

 to highlight desired decimal 

separator (comma or decimal mark).
Press ENTER to save the decimal mark selection.

7. Press 

 to move to the next selection, SELECT UNITS.

Press 

 and scroll 

 or 

 to choose Metric or 

U.S. Customary.  
Press ENTER save unit selection.
  

8. Press 

 to move to the next selection SETUP CHANNEL 1.

Press ENTER, ('Looking for Sensor Type' will appear on 
the screen).  
 

The 9950 will search for an attached S

3

L sensor on

 

Channel 1.  The found sensor type will be highlighted.  

 

 If your desired sensor is not highlighted, use the 

 or 

 to scroll through the sensor list and select 

another sensor type.  
Press ENTER to save sensor type selected.

 Press 

 or 

 to access screens to adjust common 

 sensor 

parameters. 

 

 

 = edit, ENTER = Save, 

+

= Cancel. 

 Press 

+

 to return to SETUP CHANNEL 1 screen.

9. Press 

 to move to the next selection, SETUP CHANNEL 2.

Repeat steps in number 8 to set up Channel 2. 
Press 

 to go back to Channel 1, if desired.  

When done, press 

+

 together one time exits to the 

previous menu. Press 

+

 together a second time to exit 

Easy Start Up.

System Startup: Step 3
Assign the unique operating parameters for your system.

System Setup

Содержание Signet 9950

Страница 1: ...e following modules Direct Single Channel Conductivity Resistivity Module Dual Channel Conductivity Resistivity Module Four Channel Mechanical Relay Module Optional Two Mechanical and Two Solid State...

Страница 2: ...Warranty Information Product Registration Safety Information Standards and Approvals CE UL CUL WEEE RoHS Compliant Manufactured under ISO 9001 for Quality ISO 14001 for Environmental Management and OH...

Страница 3: ...t arcing sufficient to damage the relays The RC Filter Kit or snubber part number 3 8050 396 is available as an accessory to reduce or eliminate these damaging effects Recommended for inductive loads...

Страница 4: ...mounted using the provided quick clip mounting bracket Install plug in modules first with power disconnected Next step Wiring Step 2 panel V FREQ DATA GND V FREQ DATA GND Loop1 Loop1 Loop2 Loop2 PWR P...

Страница 5: ...to eliminate fraying Insert wire tip or ferrule completely into the terminal and secure with the screw Do not allow any AC leads that may be connected to the internal relays to come in contact with l...

Страница 6: ...r Terminal 3 9950 1 or 3 9950 2 Required by the instrument 12 to 32 VDC 10 regulated 0 5 A MAX DC power input and Loop current regulated voltage require the use of a UL60950 1 or UL61010 1 certified p...

Страница 7: ...D TEMP SIGNAL SHLD 2819 2820 2821 Sanitary Tri clamp 2822 2839 2842 2839 2842 In case of noise interference connect the cable shield to earth ground Conductivity sensors connected to the Direct Conduc...

Страница 8: ...1 high 6 0 mA at 30 VDC 4 8 mA at 24 VDC 2 4 mA at 12 VDC 1 0 mA at 5 VDC Terminals accept 12 to 24 AWG wire Strip 10 to 12 mm 0 4 to 0 5 in of insulation from wire tips and tin bare ends to eliminate...

Страница 9: ...3 9950 1 MUST BE POWERED BY 12 32 VDC at 0 5 A V FREQ DATA GND V FREQ DATA GND Loop1 Loop1 Loop2 Loop2 PWR PWR CH2 CH1 DC POWER and imported par Black Red Power Supply 12 to 32 VDC Red Black PLC or R...

Страница 10: ...its of Measure GPM pH sec etc Numeric Values or labels Bar Graph Channel 2 display area Numeric Values or labels Units of Measure GPM pH sec etc Password Overview The password is required to start edi...

Страница 11: ...MM DD YYYY date format and or to scroll through other format options Press ENTER to save the date format selection 5 Press to move to the next selection SET DATE Press to scroll through the days mont...

Страница 12: ...159 001 890 9950 Conductivity Transmitter AC Power 3 9950 1 2 159 001 891 9950 Dual Conductivity Transmitter DC Power 3 9950 2 2 159 001 892 9950 Dual Conductivity Transmitter AC Power Optional Modul...

Отзывы: