Signet 2537 Flowmeter

These two functions are used to span the 4 to 20 mA output 

signal to the required range.

The factory setting is 4 to 20 mA = 0 to 10.000

Only the 20 mA span is illustrated here.

Example: Set 20 mA = 500 GPM.

Set 4 and Set 20

2s

2s

x5

x4

x2

t

T

P

t

T

P

t

T

P

t

t

T

P

t

T

P

t

T

P

t

2s

Go to next

menu item

Return to

Normal Operation

Save the new setting:

This function is available on 

these versions of the 2537.

2s

x2

x3

x5

2s

T

P

t

T

P

t

t

T

P

1.

4.

5.

6.

7.

2.

3.

K-Factor

Minimum value

Maximum value

A K-Factor is the number of pulses 

a sensor will generate for each 

engineering unit of 

#

 uid that passes 

the sensor. The factory setting is 

60.0000. Locate the K-Factor in the 

tables on page 12 and 13.

Example: Set the K-Factor to 63.5 Pulses per Gallon:

2s

Go to next

menu item

Return to

Normal Operation

Save the new setting:

Select the volumetric units for the 

#

 ow measurement.

Flow Units

Example: Set the Flow Units to Gallons per minute:

This function is available on these 

versions of the 2537.

2s 

2s 

1. 

2. 

3. 

Liters/minute

(Factory setting)

Liters/hour

Liters/day

Liters/second

Gallons/minute

Gallons/hour

Gallons/day

Gallons/second

2s

Go to next

menu item

Return to

Normal Operation

Save the new setting:

Set Contrast

This function is available on 

these versions of the 2537.

All models of the 2537 have the CONTRAST adjustment. It is 

always located at the end of the menu.

2s

x1

1.

2.

Repeat until

2s

Go to next

menu item

Return to

Normal Operation

Save the new setting:

Three levels of adjustment are 

available. The factory setting of 

3 is the highest contrast setting.

To access the adjustment, enter the 

menu and scroll until the Contrast 

display appears.

Choose:

OR

OR

This function is 

available on the above 

versions of the 2537. 

Содержание Signet 2537

Страница 1: ...Digital S3 L or 4 to 20 mA This unit can be con gured on site directly through the built in user interface The 4 to 20 mA model provides a blind current loop output The Digital S3 L model provides a...

Страница 2: ...re and concentration Utilizing sensors in applications with aggressive substances is possible On special request GF Signet can provide sensors with a different internal resin encapsulation potting tha...

Страница 3: ...when the system is in operation These con gurations are not recommended because it is dif cult to keep the pipe full Installation Pipe fittings Georg Fischer Signet offers a wide selection of install...

Страница 4: ...irectly into the conduit port For conduit with ISO threads use the black thread adapter included with the connector kit To comply with NEC requirements do not use any metal conduit in the installation...

Страница 5: ...e Dry Contact Relay requires an external power source of 24 VDC 10 The Solid State Relay requires an external power source of 5 to 24 VDC Solid State Relay requires a pull up resistor 10K ohm recommen...

Страница 6: ...key S1 is held down for three seconds the ow rate is displayed for 10 minutes before reverting back to the model name In the Multi Model if the Multi menu item is set to divider then the divided puls...

Страница 7: ...0 to 9 page 9 Mode Select the output mode Total or Divider or On OFF page 10 P Factor As PULSE DIVIDER divides input freq 1 0000 to 99999 page 10 P Factor As PULSE TOTAL multiplies K Factor 1 0000 to...

Страница 8: ...tion Save the new setting Select the volumetric units for the ow measurement Flow Units Example Set the Flow Units to Gallons per minute This function is available on these versions of the 2537 2s 2s...

Страница 9: ...ING only AVERAGING and SENSITIVITY Averaging and Sensitivity Settings Because ideal ow conditions are often impossible to achieve the ow rate is often erratic which causes erratic readings in control...

Страница 10: ...Factor MULTIPLIED by the P factor The resulting frequency is output through a relay 2s Go to next menu item Return to Normal Operation Save the new setting Select DIVIDER or TOTAL operation The facto...

Страница 11: ...hes the setpoint the 2537 will wait this long in seconds before triggering the alarm The factory setting is 0000 0 seconds 4 Program the DELAY A HI alarm will be activated when the ow rate rises ABOVE...

Страница 12: ...T020 54 468 14 391 STAINLESS STEEL TEES ON SCH 40 PIPE 1 2 CR4T005 734 20 193 98 3 4 CR4T007 412 10 108 88 1 CR4T010 252 70 66 764 1 1 4 CR4T012 128 12 33 849 1 1 2 CR4T015 77 320 20 428 2 CR4T020 45...

Страница 13: ...00 1 9868 8 CR4W080 4 3400 1 1466 CARBON STEEL WELDOLETS ON SCH 40 PIPE 2 1 2 CS4W025 37 600 9 9339 3 CS4W030 24 340 6 4306 4 CS4W040 13 920 3 6777 5 CS4W050 10 860 2 8692 6 CS4W060 7 5200 1 9868 8 CS...

Страница 14: ...it breaks the sensor cannot be repaired 3 Install the new rotor by inserting one tip of the pin into the hole then carefully ex the opposite ear back enough to slip rotor into place H Dimensions The p...

Страница 15: ...15 Signet 2537 Flowmeter Notes...

Страница 16: ...Digital S3 L Integral Mount 3 2537 6C T0 159 001 320 4 to 20 mA Integral Mount Accessories Mfr Part No Code Description 3 2536 320 1 198 820 052 Rotor PVDF Black 3 2536 320 2 159 000 272 Rotor PVDF Na...

Отзывы: