30
EN
Installation
Caution! Do not plug in the transformer with plug
(3) until startup.
Install the filter in the cold water pipes upstream
of the objects to be protected (see installation dia-
gram). Always provide stop valves.
Install the connector in the direction of flow in
a horizontal or vertical cold water pipe (observe
direction of flow arrow).
Connection to connector
Screw the filter onto the connector using 4 hexagon
screws ( 5 mm) and the seal (screws included).
Check the seal for proper fit. Tighten the screws
evenly and crosswise.
Wastewater connection
Route the wastewater connection to the drain so
that no reflux occurs.
Note: Do not bend the vent tube (5) when changing
to the hose connection (6).
Please note: According to SVGW W3 / E2d the flush-
ing water hose must be secured at a distance of at
least 20mm from the highest possible waste water
level (free discharge).
> 20 mm
> 1 m
> 400 mm
6
5
Σ
m
3
0 0 0
3
Содержание 1881.040
Страница 35: ...35 35 EN...