TS 4000 R
GB 7
Mounting and securing
Fig.: 6.2.2.3
X
Insert end caps (
1
) in sliding rail.
X
Fasten guide rail with screws (
2
).
X
Open adjustment valve (closing speed) (
3
) again.
6.3 Mains connection
DANGER!
Hazard of electric shock!
Electric wiring must only be carried out by professional electricians.
Operating voltage: 230 V AC +10 % / –15 %.
X
Interrupt power supply!
The GEZE hold-open devices FA GC are appliances of the protection class I
.
The 230 V supply line is double insulated (with cable jacket) to be inserted at least 8 mm into the terminal area.
Appliances of the protection class I are connected with a three-core cable NYM-J 3 x 1.5.
Use cable protection for the 230 V cable when leading through plaster.
Insert the 230 V cable/cable for additional connections protruding from the wall through the
respective openings of the smoke switch housing.
Fig.: 6.3.1
X
Fuse the on-site mains connection with a B10 fuse.
X
Remove cover of cable connection (
1.
).
X
Shorten 230 V power supply cable to approx. 80 mm (
2.
).
X
Place 230 V power supply cable on site on the terminal and connect (
3.
).
X
Fit cover of cable connection (
4.
).