TS 4000 R
GB 4
Mounting and securing
X
Mark out and drill fixing holes for door closer and guide rail using fitting template or cut M5 thread if necessary.
X
Drill additional hole (A) for 230V power supply.
X
If necessary, make opening for additional connections (B).
IMPORTANT:
To guarantee correct functioning of the smoke switch, GEZE recommends
that the distance between the upper edge of the door closer and the ceiling
be at least 10 mm!
>10 mm
6.1.2 Mount door closer and rod
Fig.: 6.1.2.1
X
For concealed connection, route 230 V mains cable into the terminal area (see section „Mains connection“) (
1
.).
X
Mount door closer (
2
.).
DIN left DIN right
Fig.: 6.1.2.2
TS 4000 R BG
TS 4000 RFS BG
X
Position lower part of rod and screw down (
2
.) (tigh-
tening torque: 14 Nm, closing angle approx 80°).
X
Screw lower part of rod assembly to the door
(tightening torque: 14 Nm) (
3.
).
X
Turn driver plate into the correct position (
1.
).
X
Position lower part of rod and screw down (
2
.) (tigh-
tening torque: 14 Nm, closing angle approx 80°).
X
Screw lower part of rod assembly to the door
(tightening torque: 14 Nm) (
3.
).
latching action setting
with latching action
without latching action
Fig.: 6.1.1.2