Closing sequence control

Electrical closing sequence control

In normal operation of double leaf drive units, the closing sequence of the door leaves 

is controlled by the control units of the drive units, with the passive leaf being closed 

first. The active leaf remains in the open position until the passive leaf has reached the 

closed position, then the active leaf begins to close.

Integrated closing sequence control (-IS)

In the event of a power failure, the closing sequence is controlled mechanically on double 

leaf door systems with Slimdrive EMD-F-IS. The door leaves are closed by means of the 

power storage device of the drives, with the active leaf being kept open by the integrat-

ed mechanical closing sequence control. When the passive leaf has reached the closing 

position, it releases the active leaf by means of the mechanical elements of the integrated 

closing sequence control so that it can also close completely.

Electric strike

Fail-secure electric strike

Available as AC or DC electric strike version. When the drive unit is activated, the elec-

tric strike is switched on by the control unit of the drive unit provided the door 

is in the closing position. The electric strike remains activated until the door has left 

the closing position.

Fail-safe electric strike

DC electric strike version. The electric strike is switched off when the drive unit is acti-

vated provided the door is in the closing position. The electric strike remains switched 

off until the door has left the closing position.

Bolt feedback

The bolt feedback function is a contact integrated in the lock latch that is activated 

when the door is locked mechanically by the tie bolt of the door lock. It signals to the 

control unit that the door is locked mechanically and can therefore not be opened 

by the drive unit. In this case the control unit ignores the control commands of all the 

activation devices.

Reset

Push button for restarting the drive after the operating voltage has been switched 

on or after a fire alarm has been terminated. When the push button is pressed, the 

latching integrated in the drive is activated, causing the drive to be switched on.

Latching function

When the door is closed in a de-energised state, the door leaf is impeded by the lock 

latch of the electric strike. To make sure the door can pass the lock latch safely during 

closing, an integrated limit switch is activated in the drive once a specific opening an-

gle has been reached, reducing the braking strength. The door accelerates and closes 

into the lock at increased speed. In an energised state, this function is regulated by the 

drive control unit.

Door closer mode

In automatic mode (normal operation) the automatic swing door drive can behave like 

a door closer. This means that closing is torque-controlled. This closing torque can 

be adjusted and adapted to the respective passage situation.

Servo operation

If servo operation is used, the swing door drive supports manual opening through 

moment of force. The support torque and the support period can be set for this support.

Содержание Slimdrive EMD-F-IS

Страница 1: ...for variants Slimdrive EMD 1 leaf 2 leaf Slimdrive EMD F 1 leaf 2 leaf Slimdrive EMD Invers 1 leaf 2 leaf Slimdrive EMD F IS Slimdrive EMD F R Slimdrive EMD F R IS Original operating instructions EN U...

Страница 2: ...9 3 4 3 Display programme switch DPS option 9 3 4 4 Keypad programme switch TPS optional 10 3 5 Door in normal operation 10 4 Operation 12 4 1 Selecting the mode of operation 12 4 1 1 Selecting the m...

Страница 3: ...o read the additional information carefully X X Symbol for an action This means you have to do something X X If there are several actions to be taken keep to the given order 1 2 Product liability In c...

Страница 4: ...he AUTO MATIC and EXIT ONLY modes of operation The door is opened automatically when the button is first pressed and closed again automatically when the button is pressed the second time The function...

Страница 5: ...is in the closing position The electric strike remains switched off until the door has left the closing position Bolt feedback The bolt feedback function is a contact integrated in the lock latch that...

Страница 6: ...nd are in a legible state Protect the programme switch against unauthorised access Danger of injury by sharp edges on the drive when removing the weather hood Danger of injury by parts hanging down Th...

Страница 7: ...eaf transom installation 1 Drive unit 2 Link arm or lever 3 Smoke switch control unit 1 4 Outside contact sensor KA optional 5 Mechanical contact KB optional 6 Smoke switch 1 7 Contact sensor inside K...

Страница 8: ...ted using the key switch The inside and outside activation devices are inactive OFF OFF OFF Of Door is enabled and can be moved by hand The inside and outside activation devices are inactive Mechanica...

Страница 9: ...of operation is disabled if the key provided has been removed Mechanical programme switch MPS ST with integrated key switch 3 4 3 Display programme switch DPS option Can be connected additionally to t...

Страница 10: ...n Closing safety sensor SIS is triggered while the door is closing The door immediately opens again or stops depending on the parameter setting Opening safety sensor SIO is triggered while door is ope...

Страница 11: ...rs can be set This means that 1 leaf or 2 leaf opening is possible by pressing the push button If the push button is pressed once only the active leaf opens and closes after the hold open time has exp...

Страница 12: ...switch optional In the programme settings I and II the display programme switch optional is used to display the mode of operation set and to output fault messages X X Set the internal programme switch...

Страница 13: ...ng the display programme switch is only possible when the internal pro gramme switch 20 is set to the 0 position X X Touch the required mode of operation on the display pro gramme switch The mode of o...

Страница 14: ...and keys The LED of the current operating state lights up When using a key switch X X Enable by operating the key switch once briefly Disable the operation of the keypad programme switch X X Activate...

Страница 15: ...ke does not release X X Notify a service technician Fire alarm active Slimdrive EMD F only X X Activate reset button 19 Drive defective X X Notify a service technician Door does not close After 4 minu...

Страница 16: ...e switch or control unit defective X X Notify a service technician Display of fault messages on the display programme switch Fault in the door system X X Note fault messages Up to 10 different fault m...

Страница 17: ...to the maintenance display on the display programme switch Installation maintenance and repair work must be performed by experts authorised by GEZE If a dot appears on the bottom right hand part of th...

Страница 18: ...lectrical connection values 230 V 50 Hz pursuant to DIN IEC 38 Connected load max 300 W Capacity rating 230 W Protection Mains connection 230 V on site 4 A to 16 A Current consumption for external dev...

Страница 19: ...Slimdrive EMD EMD F 19...

Страница 20: ...nce fr geze com www geze fr Hungary GEZE Hungary Kft E Mail office hungary geze com www geze hu Iberia GEZE Iberia S R L E Mail info es geze com www geze es India GEZE India Private Ltd E Mail office...

Отзывы: