GEZE SecuLogic GCER 100
8
GB | ENGLISH
Technical data
Main dimensions
60
80
1
1,7
27,7
Controller
Voltage supply
AC: 8-12 V AC (max. no-load voltage factor 1.3)
DC: Stabilised: 9-12 V DC, unstabilised: max. 20 V DC unloa-
ded
Input protected from inverse-polarity.
Current consumption
max. 150 mA
Relay contact:
Form of contact
Switching voltage
Switching current
Switching time
Opener/closer, potential-free
(can be adjusted using the slide switch behind the clamping
ledge)
max. 30 V AC / max. 40 V DC
max. 2 A AC/DC
1 - 40 sec. (can be adjusted using the potentiometer)
Temperature range
-20 °C to +50 °C (at the installed location)
IP rating
IP 20
Dimensions (W x H x D)
(with fixing plates)
45 mm x 45 mm x 17.5 mm
(55 mm x 45 mm x 17.5 mm)
Installation location
55 mm with standard switch gear
Reader
LF Low-frequency magnetic field
120 kHz - 140 kHz
Communication type
Unidirectional
Temperature range
-30 °C to +70 °C
IP rating
IP 66
Area of application
Outdoor installation / indoor installation
Cable length
10 m, cord 4 x 0.14 mm
2
Dimensions (W x H)
80 mm x 80 mm
Structure height (T
A
) / installation
depth (T
E
)
11.7 mm / 27.7 mm
Material
ASA (weather and UV-resistant)
Background lighting
Duo-LED blue / red
Reading distance
0.2 - 7 cm (depending on the transponder type, configurati-
on, as well as installation location)
Other
Distance between 2 LF readers
min. 0.75 m
Memory size
100 different transponders
Communication between
controller and reader
Safe data encryption
Interventions and manipulation ruled out
CE certification
EN 300 330 / EN 301 489 -1, -3