Powerturn
14
Preparing installation
6.2 Fitting dimensions for the installation types
6.2.1 Transom installation hinge side with standard roller guide rail
à
Hole pattern DIN left and DIN right reversed.
à
Follow different installation instructions for a sensor roller guide rail.
Fastening DIN left
Fastening DIN right
4
4
X4
X4
1
Dimensional reference centre of hinge/top edge of door
2
concealed line-feed possible in the hatched area, e.g. Ø 20 mm for the mains connection cable or low-voltage
connection (a side line-feed is also possible as an option, see chapter 7.2)
3
Directional arrow for precise positioning of the mounting plate
4
Hinge size 190 mm
Fasteners
Steel/ aluminium doors
Timber doors
Drive fastening
8 countersunk screws M6 × 25 and riveting nut M6
8 wood screws Ø6 × 50
Fastening of standard roller guide rail 2 countersunk screws M5 × 40 and riveting nut M5
2 wood screws Ø5 × 50
Space requirement and fastening of standard roller guide rail
720
691
L = 330 mm
190
30
AV
X
1
X
2
X
3
0
36
92
25
30
66
122
55
50
86
142
75
Suspension bolt
X
4
X
5
Standard
10
26
23 mm elongated
33
49
AV Spindle extension
L
Lever length
130
X
2
42
X
1
= 36 +
AV
10
10
X
4
X
5
22
50
50
50
50
7*
5
6
6
5
Base - Upper edge of door
6
Space requirement for sensors
*
important functional dimension
Содержание Powerturn
Страница 50: ...Powerturn 50 Powerturn installation check list...
Страница 51: ...Powerturn 51 Powerturn installation check list...
Страница 52: ...Powerturn 52 Powerturn installation check list...
Страница 53: ...Powerturn 53 Powerturn installation check list...
Страница 54: ...Powerturn 54 Powerturn installation check list...
Страница 55: ...Powerturn 55 Powerturn installation check list...