61
SELECTED
OPERATING MODE
VERSION
POWER SUPPLY
FACTORY
VALUE
(Amperes - Power)
SETTABLE
VALUE IN THE APP
(Amperes - Power)
ECO
CABLE AND
MOBILE
CONNECTOR
OR
FLUSH-MOUNTING
SOCKET-OUTLET
SINGLE-PHASE
20 A– 4.6 kW
20 A – 4.6 kW
18 A – 4.1 kW
15 A – 3.5 kW
13 A – 3 kW
10 A – 2.3 kW
8 A – 1.8 kW
32 A – 7.4 kW
32 A – 7.4 kW
25 A – 5.8 kW
20 A– 4.6 kW
18 A – 4.1 kW
15 A – 3.5 kW
13 A – 3 kW
10 A – 2.3 kW
8 A – 1.8 kW
THREE-PHASE
16 A – 11 kW
16 A – 11 kW
13 A – 9 kW
10 A – 6.9 kW
8 A – 5.5 kW
11.2.
VEHICLE CHARGING IN DLM MODE
This charging mode can be set using the “I-CON MANAGER” APP and completing the configuration in order to:
1. Determine the type of energy meter installed upstream.
2. Set the limit power of your domestic system
As already indicated in the previous chapters, an energy meter (code GWD6812 or GWD6817) must be installed
upstream of the electrical system and it must be connected to the charging station via the RS485 line.
The presence of the external energy meter connected to the charging station and the indication of the system
variables allow the station to manage charging in a completely autonomous manner, varying the power based on
the trend of the domestic electrical consumption, thereby optimising charging as much as possible.
To enable a recharging session:
#
Action to be carried out
RGB LED status
1
Make sure there are no errors on the charging station
Fixed green
2
Insert the charging plug in the station socket-outlet and on the
vehicle side
or
Connect the mobile connector to the car.
Fixed green
3
The station will decide if it is possible to start the charge or if it
must be kept in stand-by based on the domestic consumption
detected. The user does not have to do anything
Blue flashing
(charging in stand-by) or
Blue fixed (charging started)
At every moment, the station decides if it is possible to continue
with charging, or if it must be suspended to permit domestic
consumption. There is no action or operation that the customer
can perform
4
Charging session in progress but car battery charged
or
Session suspended due to an increase in domestic consumption
Flashing blue
5
The charging session was ended by the customer by disconnect-
ing the cable from the vehicle
Flashing green
6
If the station detects no errors, it will return to standby
Fixed green