Electric vehicle charging unit JOINON WALLBOX I-CON DLM
42
6.2.
ENVIRONMENTAL CONDITIONS
To select the most suitable location, take the environmental operating conditions of the device into consideration.
Environmental conditions
Minimum temperature
-25°C
Minimum temperature of the surrounding air
-25°C
Maximum temperature of the surrounding air
+50°C
Maximum relative humidity without condensation
95%
Remember that it could occasionally produce a small amount of condensation as a result of temperature changes.
Therefore, in addition to the protection it has, the charging stations must be monitored when they are used in
areas where it is probable that not all the previously indicated conditions will be satisfied.
Never connect the device to the voltage supply when there is condensation.
6.3.
SUPPORT AND FASTENING SURFACE
To ensure correct heat dispersal and a good hold, the recharging stations must be installed on a perfectly vertical
wall.
The wall on which the device is fastened must be solid. It must be possible to drill the wall and insert wall plugs
and anchor bolts that are suitable for supporting the device weight.
To decide the location of the device and prepare for its installation, a series of instructions connected to the prop-
erties of the device must be followed.
6.1.
ENVIRONMENT
• Position the charging station in a location that can be accessed for installation and maintenance, which permits
its use and the reading of the LED indicators.
• Avoid corrosive environments that could have an influence on the correct operation of the device.
• It is prohibited to leave any object on the device.
PREPARATION FOR DEVICE INSTALLATION
6.