Red LED
Green LED
Sound
Description
Solution
Flashes briefly
approximately
every 5 min
-
-
Ready/normal mode
Smoke alarm device is working
correctly and is ready for
smoke detection.
Briefly press the button to
temporarily silence the alarm
preventatively for 10 ± 1 minutes.
Flashes approx.
twice per second
-
Intermittent alarm
signal
Alarm is triggered when
smoke is detected.
Temporarily silence the alarm for
10 ± 1 minutes by briefly pressing
the button.
Flashes approx.
every 10 seconds
-
No signal
Temporary silencing of the
alarm
is activated for 10 ± 1 min.
Silent mode can be cancelled by
initiating the test function: Press
and hold the button (min. 3 sec.)
until a loud, pulsating alarm signal
sounds.
Flashes approx.
every 10 seconds
-
3 short beeps in 43
seconds
Error/sensor fault/end of life
Replace the device
Flashes approx.
every 5 min
-
Tone every 43
seconds
Fault signal emitted by the
smoke alarm device when
battery is discharged
Replace the device
-
Flashes 3x
every 43
seconds for 24
hours
No signal
Alarm memory for the next 24
hours
The alarm memory can be
cancelled by pressing the silencing
button.
11
Table of functions
DE
GB
FR
IT
PL