<Doc_USR><Doc_5025919000><Rel_A><Lang_EN>
Page 18 of 24
Alarms
If the red lamp at
O
lights up, the process has been aborted because of a fault.
The display shows a fault code.
Acknowledging a fault code
Acknowledge the fault code as follows:
Note the fault code
•
Cancel the acoustic signal by pressing
•
U
. The machine remains locked but the
program has been stopped. The display shows the password entry menu.
Correct the fault or call service personnel.
•
Enter the password (558387) using the arrow keys and press
•
S
. All liquid is
drained from the machine and the soiled-side door is unlocked*.
Open the door and remove the items.
•
The items in the machine are not clean and must be washed again from the
beginning with a new program.
If the items are still hot, handle them with care to avoid burns.
* If the drain pump is faulty, water cannot be drained from the machine and the fault cannot be put
right until the door has been opened. The soiled-side door is unlocked as soon as the password
is confirmed.
F01
Fault codes in the machine
Fault codes indicate that a serious fault has occurred in the machine or the washing
process . The fault must be put right by an authorized service technician.
The following fault codes may occur:
Fault code
Description of fault
A00 POWER FAIL
Power failure
A01 MCCB TRIP
Tripped overload protection
A02 CH SLOW FILL
Chamber tank slow to fill. The chamber tank takes more than 10 minutes to fill.
A03 SLOW DRAIN
The chamber takes more than 5 minutes to drain.
A04 W LEAK DRYER
Water leakage in the dryer
A05 LOCK SS
Soiled-side door does not lock within 3 seconds of program start or the door is
unlocked while a program is running.
The soiled-side breakers for locked and unlocked are activated at the
same time.
A06 UNLOCK SS
Soiled-side door does not unlock within 3 seconds after the end of a program.
A07 CLOSED SS
The soiled-side door did not close within 20 seconds of program start or the
door is open while a program is running or the crush protection was activated
while a program was running.
The soiled-side breakers for open and closed are activated at the same time.
A09 LOCK CS
Clean-side door does not lock within 3 seconds of program start or the door is
unlocked while a program is running.
The clean-side breakers for locked and unlocked are activated at the
same time.