Страница 1: ...USER INSTRUCTIONS FOR GET PORTABLE 6k BTU AIR CONDITIONER MODEL No GPACU6 ...

Страница 2: ...CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Troubleshooting Maintenance Energy saving tips Specification ...

Страница 3: ...lti functional room air exchanging air processing appliance designed to offer you the functions of Air Conditioning Dehumidifying and Independent Fan control This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance Read these instructions fully before operating the unit and retain them for future reference If properly maintained yo...

Страница 4: ...is fitted with an approved BS 1363 13A 3 pin plug and a 13A BS 1362 fuse In the event of either requiring replacement ensure that equivalent rated and approved components are used See plug replacement details below 11 IMPORTANT If this unit is sited in a room containing a fuel burning appliance the installer must ensure that the air replacement is sufficient for both the unit used as an air condit...

Страница 5: ...Warning In order to ensure the long reliable and safe functioning of the air conditioner the following safety points should be observed ...

Страница 6: ...iption 1 Control Panel 2 Cool Air Outlet See note below 3 Handle Recess 4 Castor 5 Air Filter 6 Exhaust Air outlet 7 Air Intake 8 Built in Cable Storage 9 Water Drain Outlet 10 Power Supply Cord Please manually open the air outlet item 2 to desired position ...

Страница 7: ...the back of the machine Care should be taken to ensure that the two rectangular cut outs in the connector are located over the two moulded fingers positioned on the diameter of the machine outlet The connector can be removed from the machine by rotating it slightly and pulling it away from the machine at the same time The exhaust nozzle should be fitted to the exhaust nozzle connector on the free ...

Страница 8: ...bject Do not install the unit underneath desks or inside cupboards as this will restrict the operating air flow Ensure that there are no obstructions to the air intake or air outlet Ensure that the air intake is not being blocked by curtains or similar objects The end of the vent hose should not be blocked by a shutter or similar device When fitting the vent hose it should be kept as straight as p...

Страница 9: ...e If this is the case do not attempt to operate the machine and call the service number Mode Indicator Note Modes are selected by means of the remote controller a When COOLING MODE is selected the LED will illuminate BLUE b When DEHUMIDIFYING MODE is selected the LED will illuminate ORANGE c When FAN MODE is selected the LED will illuminate GREEN Note In Cooling and Fan mode the fan speed can be s...

Страница 10: ...Button This button is used to switch the machine on and off MODE This button is used to select the modes as follows Cooling Mode LED illuminates Blue In this mode the air is cooled and hot air is exhausted through the vent hose to outside the room Fan speed and temperature can be adjusted to suit the comfort level required by means of the appropriate buttons on the remote controller Dehumidifying ...

Страница 11: ...ely 5 seconds the display will revert to showing the room temperature Timer mode a Auto Turn Off With the machine on and running set the timer to select the number of hours you would like the unit to run until it automatically shuts off Timer mode b Auto Turn On Switch the machine on using the ON OFF button either on the machine itself or on the remote controller so that the machine is running and...

Страница 12: ...N Tank is full Reset the temperature level Reset the timer Remove the obstruction Drain the water tank Air conditioner runs intermittently Malfunction Surrounding temperature is too high or too low Heat exhaust hose is blocked Contact the service centre Check the hose Air conditioner functions but the room is not cooled Window or door is left open in the room There is a heat source or too many peo...

Страница 13: ...ent Rinse the filter and allow to dry Replace the filter by engaging the top edge and clipping the bottom into place Replace the front grille by engaging the tabs on the top edge into the slots at the top of the aperture of the front of the machine and clip the bottom of the grille into place Maintenance on the front panel and housing Do not use chemicals or solvents for cleaning the unit Use a da...

Страница 14: ...ake sure you check and clean the filter each week If the filter is not kept clean it can increase your power consumption and reduce the cooling efficiency Take note of the following points Avoid direct sun light on the unit through a window Maintain proper ventilation around the unit Avoid opening doors and windows as much as possible Avoid excess number of people in the room ...

Страница 15: ...g capacity 1 8kW Dehumidifying capacity 1 4 L hour Coolant R 407C 515g Timer 24 hour Air flow volume 240m hour Dimensions W X H X D 485 X 612 X 337mm Weight N W 25 3kgs NOTE Waste electrical products or products containing refrigerants should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice GET Plc Key Po...