Timer  

Press the Timer button to set the timer. The green LED next to the ON/OFF legend will flash on and off for 
15 seconds. 
While the green LED is flashing, press the timer/temp adjust buttons (

▲▼

) to select the time (in hours, 

between 00 and 24) for either of the timer modes “a” or “b” as detailed below.  The time selected is shown on 
the display panel.  After the 15 seconds the display will revert to showing the room temperature.     
If no time has been selected the timer will be off and the green LED will not be illuminated. 
    

Timer mode a)  Auto Turn Off

:-  With the machine on and running press Timer and then the Timer/Temp 

Adjust buttons (

▲▼

) to select the number of hours you would like the unit to run until it automatically shuts 

off.  The green timer LED will remain lit. 
 

Timer mode b)  Auto Turn On

:-   Switch the machine on using the Power button so that the machine is 

running and the desired mode is selected.  Press the power button again to put the machine into stand-by 
mode.  With the machine in stand by mode, press the Timer button and then press the Timer/Temp Adjust 
buttons (

▲▼

) to select the number of hours until it is required for the machine to start up automatically.  The 

green LED will continue to flash and the display will show the time set. 

 

Timer/Temperature Adjust buttons 

In Cooling or Dehumidifying mode, the temperature can be manually set by pressing the Timer/Temp Adjust 
buttons (

▲▼

) between the limits of 16° to 32°C as shown in the display panel.  This cannot be done in Fan 

mode or heating mode.  The default setting is room temperature.   After 15 seconds the display will revert 
back to room temperature. 
 

IMPORTANT 

When the appliance is in Cool or Dehumidifier mode, most moisture will be vented out through the vent pipe.  
However, in certain circumstances some condensation may collect in the water tank at the bottom of the 

chassis.  When this tank is full, the “water full” indicator (

) will illuminate (red) and the appliance will stop 

running. The appliance should then be unplugged from the supply socket and the rubber plug in drain port at 
the lower rear

 

of the machine should be pulled out to drain the water into a suitable container. Alternatively, 

move the appliance to a suitable place to drain the water. 

 

Note: When the water full light 

(

)

 is on, the water should be drained out.   If 

the water is not drained out, the appliance will not operate. 

Содержание GPACU12HR

Страница 1: ...USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No GPACU12HR ...

Страница 2: ...CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting ...

Страница 3: ...lti functional room air exchanging air processing appliance designed to offer you the functions of Air Conditioning Dehumidifying Heating and Independent Fan This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance Read these instructions fully before operating the unit and retain them for future reference If properly maintained yo...

Страница 4: ...eplacement ensure that equivalent rated and approved components are used See plug replacement details below 9 IMPORTANT If this unit is sited in a room containing a fuel burning appliance the installer must ensure that the air replacement is sufficient for both the unit used as an air conditioner and the fuel burning appliance PLUG REPLACEMENT If the plug is damaged and requires replacement follow...

Страница 5: ...Identification of Parts 1 Control Panel 2 Cold air outlet 3 Remote control receiver window 4 Transport handle 5 Air outlet hose 6 Evaporator air intake 7 Air intake 8 Drain port 9 Mains lead ...

Страница 6: ...o allow the vent hose to reach outside the room The air intake should be a minimum distance of 50cm from any object Do not install the unit underneath desks or inside cupboards as this will restrict the operating air flow Ensure that there are no obstructions to the air intake or air outlet Ensure that the air intake is not being blocked by curtains or similar objects The end of the vent hose shou...

Страница 7: ...able wall venting kit details available from the Helpline which also contains an external grille and hose to pass through the wall 1 Make a suitable size hole through the external wall to accept the hose in the wall venting kit 2 Secure the flexible ducting in the wall venting kit to the wall fitting using cable ties 3 Pass the flexible ducting through the hole in the wall from the inside 4 Fix th...

Страница 8: ...o HEATING FAN legend will illuminate yellow Note In Cool Heating and Fan modes the fan speed can be set to High Medium and Low When Dehumidifier mode is selected and the room temperature is below 25 C the fan speed is automatically set to medium and cannot be altered from this setting When the room temperature is above 26 C the fan speed is adjustable Cool Mode In this mode the air is cooled and h...

Страница 9: ...o select the number of hours until it is required for the machine to start up automatically The green LED will continue to flash and the display will show the time set Timer Temperature Adjust buttons In Cooling or Dehumidifying mode the temperature can be manually set by pressing the Timer Temp Adjust buttons between the limits of 16 to 32 C as shown in the display panel This cannot be done in Fa...

Страница 10: ...REMOTE CONTROL UNIT ...

Страница 11: ...o the supply socket Run a short while only The set temperature is close to room temperature Try lowering the set temperature Air outlet is blocked by obstacle Remove obstacle Run but not cool The door or window is open wide There is another heating appliance working in the room like heater or lamp etc The air filter is dirty Clean it Air outlet or intake is blocked Set temperature is too high Redu...

Страница 12: ...ater about 40 C with a neutral detergent Rinse the filter and allow to dry Replace the filter by sliding it down into the back of the unit 2 If the appliance will not be used for a long time it is important to pull out the rubber plug from the drain port at the lower rear of the machine in order to drain the water 3 Take the batteries out of the remote controller and keep it in a safe place 4 Clea...

Страница 13: ...ing 6 2 A Operating Cycle Heating 6 1 A Cooling Capacity 12000BTU Hr 3 5 kW Heating Capacity 3 2 kW Dehumidifying capacity 2 2 L hour Coolant R 410A Timer 24 hour Dimensions W X H X D 50 cm X 84 5 cm X 40 cm Weight N W 36Kg NOTE Waste electrical products and products containing refrigerants should not be disposed of with household waste Please recycle where facilities exist Check with your local a...

Отзывы: