Maintenance  
 

         

 

 

                                 

 

Maintenance  

 

1.  The air filter should be cleaned periodically.  The intervals between cleaning will depend 

on the amount of airborne dust in the area in which the unit is used.  The air filter is 
removed by sliding it vertically upwards from out of the back of the unit. 
Wash the filter by immersing it gently in warm water (about 40°C) with a neutral 
detergent.  Rinse the filter and allow to dry.  Replace the filter by sliding it down into the 
back of the unit   

2.  If the appliance will not be used for a long time, it is important to pull out the rubber plug 

from the drain port at the lower rear of the machine, in order to drain the water. 

3.  Take the batteries out of the remote controller and keep it in a safe place. 
4.  Clean the air filter and reinstall it. 
5.  Remove the air hose and keep it in a safe place.  
6.  Cover the unit and store in a dry place. 

 
 
 

Содержание GPACU12HR

Страница 1: ...USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No GPACU12HR ...

Страница 2: ...CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting ...

Страница 3: ...lti functional room air exchanging air processing appliance designed to offer you the functions of Air Conditioning Dehumidifying Heating and Independent Fan This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance Read these instructions fully before operating the unit and retain them for future reference If properly maintained yo...

Страница 4: ...eplacement ensure that equivalent rated and approved components are used See plug replacement details below 9 IMPORTANT If this unit is sited in a room containing a fuel burning appliance the installer must ensure that the air replacement is sufficient for both the unit used as an air conditioner and the fuel burning appliance PLUG REPLACEMENT If the plug is damaged and requires replacement follow...

Страница 5: ...Identification of Parts 1 Control Panel 2 Cold air outlet 3 Remote control receiver window 4 Transport handle 5 Air outlet hose 6 Evaporator air intake 7 Air intake 8 Drain port 9 Mains lead ...

Страница 6: ...o allow the vent hose to reach outside the room The air intake should be a minimum distance of 50cm from any object Do not install the unit underneath desks or inside cupboards as this will restrict the operating air flow Ensure that there are no obstructions to the air intake or air outlet Ensure that the air intake is not being blocked by curtains or similar objects The end of the vent hose shou...

Страница 7: ...able wall venting kit details available from the Helpline which also contains an external grille and hose to pass through the wall 1 Make a suitable size hole through the external wall to accept the hose in the wall venting kit 2 Secure the flexible ducting in the wall venting kit to the wall fitting using cable ties 3 Pass the flexible ducting through the hole in the wall from the inside 4 Fix th...

Страница 8: ...o HEATING FAN legend will illuminate yellow Note In Cool Heating and Fan modes the fan speed can be set to High Medium and Low When Dehumidifier mode is selected and the room temperature is below 25 C the fan speed is automatically set to medium and cannot be altered from this setting When the room temperature is above 26 C the fan speed is adjustable Cool Mode In this mode the air is cooled and h...

Страница 9: ...o select the number of hours until it is required for the machine to start up automatically The green LED will continue to flash and the display will show the time set Timer Temperature Adjust buttons In Cooling or Dehumidifying mode the temperature can be manually set by pressing the Timer Temp Adjust buttons between the limits of 16 to 32 C as shown in the display panel This cannot be done in Fa...

Страница 10: ...REMOTE CONTROL UNIT ...

Страница 11: ...o the supply socket Run a short while only The set temperature is close to room temperature Try lowering the set temperature Air outlet is blocked by obstacle Remove obstacle Run but not cool The door or window is open wide There is another heating appliance working in the room like heater or lamp etc The air filter is dirty Clean it Air outlet or intake is blocked Set temperature is too high Redu...

Страница 12: ...ater about 40 C with a neutral detergent Rinse the filter and allow to dry Replace the filter by sliding it down into the back of the unit 2 If the appliance will not be used for a long time it is important to pull out the rubber plug from the drain port at the lower rear of the machine in order to drain the water 3 Take the batteries out of the remote controller and keep it in a safe place 4 Clea...

Страница 13: ...ing 6 2 A Operating Cycle Heating 6 1 A Cooling Capacity 12000BTU Hr 3 5 kW Heating Capacity 3 2 kW Dehumidifying capacity 2 2 L hour Coolant R 410A Timer 24 hour Dimensions W X H X D 50 cm X 84 5 cm X 40 cm Weight N W 36Kg NOTE Waste electrical products and products containing refrigerants should not be disposed of with household waste Please recycle where facilities exist Check with your local a...

Отзывы: