6
TRS 5-52 - Installation & Operating Manual -
819175-05
TRS 5-52
Supply voltage
24 VDC +/– 20%
Fuse
external 0.5A (semi-delay)
Power consumption
4 W
Connecting the temperature sensor
1 input for TRG 5-63, TRG 5-64, TRG 5-65, TRG 5-66, TRG 5-67 and TRG 5-68 temperature sensors,
(Pt100 platinum resistance thermometer to EN 60751), 3-pole with shield.
Outputs:
2 volt-free relay contacts, 6 A 250 V AC / 30 V DC cos
ϕ
= 1.
(MIN/MAX alarm, adjustable switchpoint).
Inductive loads must have interference suppression (RC combination) as per the manufacturer's
specification.
1 analogue output 4-20 mA, max. output load 500 ohms, e.g. for actual value indication (optional).
Measuring range
0 °C to 600 °C
Switching hysteresis
MAX temperature switchpoint: –5 K, fixed.
MIN temperature switchpoint: +5 K, fixed.
Displays and controls
1 rotary knob with integrated pushbutton for testing the MIN/MAX alarm and setting the parameters,
1 four-digit seven-segment LED display, green
2 red LEDs for MIN/MAX alarm
Housing
Housing material base of black polycarbonate; front of grey polycarbonate
Conductor size: 1 x 4.0 mm
2
solid per wire, or
1 x 2.5 mm
2
per stranded wire with sleeve to DIN 46228, or
2 x 1.5 mm
2
per stranded wire with sleeve to DIN 46228 (min.
∅
0.1 mm)
Terminal strips can be removed separately
Housing attachment: Mounting clip on support rail TH 35, EN 60715
Electrical safety
Pollution degree 2 for installation in control cabinet with protection rating IP 54, fully insulated
IP rating
Housing: IP 40 to EN 60529
Terminal strip: IP 20 to EN 60529
Panel adapter: IP 65 to EN 60529
Weight
approx. 0.2 kg
Technical data