22
Decommissioning
Exchanging the conductivity switch
1. Switch off mains voltage.
2. Undo cover screws
8
and remove the housing cover
9
.
(Fig. 2, 3)
3. Detach mains and control cables from terminal strips
a
and pull lines out of the cable glands.
4. Detach connecting line to conductivity electrode.
5. Remove conductivity switch.
6. Install and connect new conductivity switch.
7. Attach connecting line to conductivity electrode.
8. Apply mains voltage.
Danger
The terminal strips of the conductivity switch LRS 1-7 are live during operation.
This presents the risk of severe cases of electric shock!
Always
cut off power supply
to the equipment before mounting, removing or connecting
the terminal strips!
Disposal
Dismantle the conductivity switch and separate the waste materials, using the material specification
as a reference. Electronic component parts such as the circuit board must be disposed of separately!
For the disposal of the conductivity switch observe the pertinent legal regulations concerning waste
disposal.