Basic safety notes
Risk of severe injuries
The unit may become hot during operation.
Do not operate the unit unless thermal
insulation or protection against accidental
contact prevents you from touching hot
surfaces.
The unit is under pressure during operation
and may be hot. Before carrying out any
work on the unit make sure that the
following requirements are met:
The pipes and the unit must be shut
off depressurized (0 bar).
The higher-level system must be
switched off.
The fluid must be completely removed
from the unit.
The pipes and the unit must have
cooled down to room temperature
(approx. 20 °C)
If the unit is used in contaminated areas
there is a risk of severe injuries or death
caused by harmful substances in or on the
unit. Before working on the unit make sure
that it is completely decontaminated.
Always wear the protective clothing
prescribed for contaminated areas when
working on the unit.
The unit must only be used with fluids that
do not attack the material and the gaskets
and sealings of the unit. Otherwise leaks
may occur and hot or toxic fluid could
escape.
The unit and its component parts must only
be mounted or removed by qualified
personnel. A qualified person must be
acquainted with and experienced in the
following:
Making pipe, vessel and tank
connections.
Selecting suitable lifting gear and
understanding the rules for its safe
use.
Working with dangerous
(contaminated, hot or pressurized)
fluids.
The electrical personnel must also
have knowledge and experience in
electrical connection as well as of the
current and mains voltage used.
If the admissible pressure and temperature
ratings are exceeded, the unit may be
destroyed and hot or pressurised fluid may
escape. Make sure that the unit is always
used within the admissible pressure and
temperature ratings. You can find
information on the pressure and
temperature ratings on the name plate.
If unsuitable lifting gear is used or the gear
is used improperly the unit or parts of it
could fall down.
Make sure that only qualified personnel lifts
the unit or parts of it.
Make sure that nobody is standing or
working below the hoisted unit.
Make sure that the lifting gear is of
sufficient strength for the load to be hoisted
and that the load is properly secured and
attached to it. For more information on the
nature and weight of the components and
safe lifting points please contact the
manufacturer.
Connections to the control cabinet as well
as troubleshooting on the connected
devices may only be made by trained
GESTRA employees or specially trained
electronics technicians. When working on
electrical equipment, the operator must
ensure a mains separation device.
Make sure that all locally applicable
regulations on safety and the prevention of
accidents are strictly adhered to.