GESTRA FPS 11 Скачать руководство пользователя страница 3

3

Foreword 

This Installation & Operating Manual will help 

ensure proper, safe and cost-efficient use of the 

following types of vessel:

  Steam-powered condensate-return unit FPS 11

  Steam-powered condensate-return unit FPS 14

  Steam-powered condensate-return unit FPS 23

Referred to below simply as ‘equipment’.

This Installation & Operating Manual is intended 

for all persons bringing this equipment into ser-

vice, and operating, using, servicing, cleaning or 

disposing of the equipment. In particular, the In-

stallation & Operating Manual is aimed at service 

technicians, trained specialist personnel, and 

qualified and authorised operating personnel.

Each of the above must have read and under-

stood the content of this Installation & Operating 

Manual.

Following the instructions in the Installation & 

Operating Manual helps to avoid danger and 

increases the reliability and service life of the 

equipment. In addition to the instructions in this 

Installation & Operating Manual, compliance with 

the applicable binding rules on accident preven-

tion in the country and location of use, and with 

the generally recognised technical regulations for 

safe and proper working, is essential.

Availability

Always keep this Installation & Operating Manual 

together with the system documentation. Make 

sure that the Installation & Operating Manual is 

available to the operator.

The Installation & Operating Manual is part of the 

equipment package. Hand over this Installation 

& Operating Manual if you sell or pass on the 

equipment to a third party.

 

Formatting features in the docu-
ment 

Different types of information in the Installation 

& Operating Manual are formatted in different 

ways.

This helps you to distinguish easily between the 

following types of information:

Normal text

Cross references

 Lists

  Bullet points in lists

 Action to be taken.

These tips contain additional informa-

tion, e.g. about cost-efficient use of the 

equipment.

Security
Usage for the intended purpose

The FPS equipment uses booster steam to collect 

and transport condensate at intervals that vary 

depending on the level. The transport intervals 

are controlled by a special float valve.

The equipment may only be used within the 

admissible pressure and temperature ratings, 

with due consideration of chemical and corrosive 

influences.

Usage for the intended purpose also includes 

reading and adhering to all instructions in this 

manual, particularly the safety notes.

Any other use of the equipment shall be consid-

ered as improper use.

Improper use also includes using equipment 

made of materials that are unsuitable for the 

fluid used.

Содержание FPS 11

Страница 1: ...EN English Original Installation Operating Manual 818887 01 Steam Powered Condensate Return Unit FPS 11 FPS 14 FPS 23 FPS 14 FPS 23 FPS 11 8 ...

Страница 2: ...quipment 6 Purpose and function 8 Application of European Directives 9 Storing and transporting the equipment 9 Storing the equipment 9 Transporting the equipment 10 Installing and connecting the equipment 10 Preparing for installation 10 Connecting the equipment 10 Operation 13 After operation 13 Removing external dirt 14 Servicing the equipment 14 Taking out of service 14 Removing harmful substa...

Страница 3: ...eep this Installation Operating Manual together with the system documentation Make sure that the Installation Operating Manual is available to the operator The Installation Operating Manual is part of the equipment package Hand over this Installation Operating Manual if you sell or pass on the equipment to a third party Formatting features in the docu ment Different types of information in the Ins...

Страница 4: ...ipment can become hot during oper ation Only bring the equipment into service if contact with hot surfaces is prevented by insulation or other protection w The equipment is under pressure and can get hot Only perform work on the equipment if the following conditions are satisfied w The pipes must not be under pressure w All fluid must be thoroughly removed from pipes and the equipment w Before car...

Страница 5: ...ays be installed w The steam pressure of the system must always be higher downstream of the FPS than upstream of it w The minimum height difference must be complied with w The condensate line upstream of the equipment must be sufficiently large to act as a reservoir for condensate arising during the pumping process A pipe elbow must be installed immediately upstream of the equipment to allow the v...

Страница 6: ...müssen Sie die Komponenten verbinden und die Akkus aufladen Folgende Bestandteile sind im Lieferumfang enthalten Anzeigegerät Akku im Anzeigegerät fest installiert Schallaufnehmer inklusive Kabel Ledertasche Ladegerät inklusive Kabel Bedienungsanleitung 6 Gestaltungsmerkmale von Warnhinweisen im Text GEFAHR Hinweise mit dem Wort GEFAHR warnen vor einer gefährlichen Situation die zum Tod oder zu sc...

Страница 7: ... Condensate outlet 4 Connection Booster steam No Designation 5 Connection Vent 6 Connection Drain FPS 14 7 Name plate 8 Non return valve Description of equipment The equipment features the following connec tions w Condensate inlet w Condensate outlet w Booster steam w Vent w Drain if applicable FPS 11 FPS 14 FPS 23 ...

Страница 8: ... process the flow of conden sate builds up in the supply line When the ball float reaches the lower switch point the valve control stops the supply of boost er steam and the vent valve opens The flow of condensate accumulates in the equipment and the process is repeated The non return valve in the inlet prevents con densate and booster steam from flowing back through the condensate inlet The non r...

Страница 9: ...he following ambient conditions w Air humidity below 50 non condensing w Clean room air not salty or corrosive in other ways w Temperature 5 40 C Make sure that these conditions are constant ly maintained throughout storage Please contact the manufacturer if you wish to store the equipment in different conditions Application of European Directives Pressure Equipment Directive The equipment conform...

Страница 10: ...nnected equipment can result in accidents with extremely severe injuries or death Make sure that only specialist per sonnel connect the equipment to the pipe Remove the plugs before installation Store the plugs and packaging for later use Transporting the equipment DANGER Risk of crushing from falling equipment or components Always use suitable lifting gear when lifting moving and working on the e...

Страница 11: ...equip ment is not subjected to any forces or torques The plant operator is responsible for making sure that the equipment and sealing material are suitable for the fluid used Make sure that the materials of all equipment components are suitable for the fluid used If you require further information please contact the manufacturer Inspect all gaskets before installation to ensure they are in perfect...

Страница 12: ...M K K H H I A C F B D E G 1 FPS A Steam line B Consumer C Reservoir D Booster steam line E Vent F Condensate inflow to FPS G Condensate to boiler house H Shut off valve I Pressure gauge J Sight glass K Steam trap L Dirt trap M Non return valve ...

Страница 13: ...el to perform work on contaminated equip ment Wear the protective clothing specified for the contaminated zone during all work Make sure that the equipment is fully decontaminated before any work Follow the instructions for handling the harmful substances in question Attention Frost damage can occur when the system is not in operation Drain the equipment if there is a risk of frost Make sure the c...

Страница 14: ...emoving external dirt Remove dirt from the equipment with clean water and a lint free cloth Remove stubborn dirt with a cleaning agent suitable for the material and a lint free cloth Servicing the equipment The equipment does not require any particular maintenance work The plant operator may need to adapt the inter vals for internal inspections for corrosion and deposits depending on the condition...

Страница 15: ...e equipment and using it at a different location w Make sure that all fluid residues have been removed from the equipment w Make sure that the connections are in perfect condition Only use the equipment in the operating conditions specified for new equipment Returning the equipment You can return the equipment to your contractual partner Register the return delivery with your con tractual partner ...

Страница 16: ...TRA AG Printed in Germany GESTRA AG Münchener Strasse 77 28215 Bremen Germany Tel 49 421 3503 0 Fax 49 421 3503 393 E mail info de gestra com Website www gestra com You can find our authorised agents around the world at www gestra com ...

Отзывы: