background image

7

5.

 Precautions

A.

   Before operating your handpiece, be sure that the Collet Release Ring is 

in the “S” or secure position. Failure to do so (referred to as “locked rotor 
condition”) will cause the motor to stall and could possibly cause motor 
damage.

B.

   Do not attempt to change tools or rotate the Collet Release Ring while the 

handpiece is running. This action will stop the motor abruptly, cause parts 
damage, and could also possibly cause motor damage.

C.

   During use, avoid stalling the motor by pushing too hard on the work tool 

or by exceeding the torque capacity of the handpiece motor.

D.

   The Gesswein Power Hand 3 Rotary Handpiece is designed not to 

overheat with normal use. It can be used continuously and will provide 
efficient, longlife performance if you apply just enough machining and 
polishing pressure to maintain full motor speed.

E.

   The 

3

32

" (2.35mm), 

1

8

" (3.2mm) and 3.0mm collets are manufactured to 

accept 

3

32

", 

1

8

" and 3.0mm ± 0.0008" shank tools respectively. Use only 

tools that correspond to the collet size being used.

F.

   Do not use your handpiece in water or oil, and never allow any oil, water 

or other fluids, dirt, or wood dust to enter the inner casing. Failure to 
keep foreign matter out of the inner casing will cause damage to the ball 
bearing assemblies.

G.

   Do not subject the power cord on the handpiece to sharp bending or 

rough treatment. Such treatment could break the cord wires or damage 
the male connecting pins and female cord connectors.

H.

   Be careful not to point the handpiece at any part of the body while it is 

running, particularly during startups.

I.

   Be careful when using Wire Burnishing Tools. 

DO NOT USE THESE TOOLS 

AT SPEEDS FASTER THAN 14,000 -15,000RPM

. Each tool is made of 

individual piano wire. Operating a Wire Burnishing Tool at higher than 
recommended speed could cause the wire to come free from the hub.

8

6.

 Replacement of carbon brushes

Gesswein Power Hand 3 motors use a spring tension-type carbon brush 
assembly. The approximate life of these brushes is 800-1,000 hours. Use the 
set of two replacement carbon brushes supplied with your handpiece when 
it becomes necessary to replace worn brushes. (Brushes should be changed 
when handpiece is not running at maximum speed, or if it sounds as though 
it’s running out of gas.) Please note that in the event you must change the 
brushes, it is important that both be replaced at the same time. Replacement 
of only one carbon brush will cause motor damage.

Instructions for replacing carbon brushes

1. Disconnect the handpiece from the controller.
2. Remove the screw on the back of the motor cover.
3.  Detach the motor cord from the motor by grasping the motor cord and 

pulling backwards. Do not hold the motor cap when pulling backwards  
to avoid damaging the On/Off switch (Fig. 4).

Fig. 4

Содержание PH3 15X

Страница 1: ...3300 For use with Gesswein Power Hand 2X controllers the PH3 adaptor 510 3304 is necessary to connect the 5 prong motor plug to the 3 prong controller receptacle Controllers convert the Alternating Cu...

Страница 2: ...elease Ring toward the arrow pointing to the R or release position see Fig 2 When in full R position the Collet Release Ring will make a click sound the collet is then fully open and ready to accept a...

Страница 3: ...ll S position and that the collet rotates freely when turned by hand If the collet does not rotate freely it is not fully seated in the Head Assembly and you must repeat the removal replacement proced...

Страница 4: ...ct the power cord on the handpiece to sharp bending or rough treatment Such treatment could break the cord wires or damage the male connecting pins and female cord connectors H Be careful not to point...

Страница 5: ...with a dry brush If necessary use a cloth moistened with detergent to clean the cover and blow into the air cooling vents to clean around the armature DO NOT USE any volatile liquid as a cleaner i e...

Страница 6: ...g Cover KB 590 8960063 Coil Spring KP 036B 5010100 501 0100 Collet Chuck 2 35mm KP 032B 5010106 Collet Chuck 3 0mm KP 033B 5010105 Collet Chuck 3 175mm JA15 101 8960064 Chuck Case KB 570 8960065 Coil...

Страница 7: ...Spacer KA20 105 BB 510 2316 Armature Complete KA20 105 510 2317 Armature KF 203A 896 0010 Dust Proof Collar KF 210 896 0011 Dust Proof Collar 1030ZZ 510 3073 Ball Bearing S 10 896 0012 O Type Rubber R...

Страница 8: ...o standard and one high speed A selection of 8 heads Two reciprocating profilers One side to side profiler Belt Sander Power Hand 3 controllers and handpieces combine to create the most versatile fini...

Отзывы: