Standalone HVAC Room Energy Sensor 

 

 

 

 

G

G

G

G

ESA

ESA

ESA

ESA

 

 

Wiring Technique 

CAUTION 

  HVAC units may contain AC mains power. To prevent electric shock, ensure that AC mains is OFF before 

connecting with HVAC units.  

  Do NOT take shortcuts when connecting the HVAC power circuits. 

 

Wiring Techniques 

Conceal the sensor wiring by “fishing” the wire from hollow wall or partition. 
Drill an adequate hole behind the sensor, so that the sensor can cover the hole. 
Drop a string with a small weight inside the wall to bottom. 
Drill another hole on wall at the carpet level. Use a stiff wire with a hook to pull the string out from the hole. 
Pull the cable to the door switch, HVAC unit and slave sensor, if necessary 
Use proper tool to tuck the wire under the edge of carpet. 
Alternatively, staple the wire in the corner and cover it with vinyl corner molding to match room decor. 
Wiring should be completed and concealed in a manner that it will not be damaged by hotel guest or housekeeper. 

 

Mount the Sensor (GH-MS1) 

1. Remove the sensor cover by releasing the locking screw at the bottom of the housing. 
2. Carefully remove the circuit board by releasing the fixing screw. 
3. For corner mount (recommended), use the mounting holes on both 45° slopes to mount the base. 
4. Lead the cable into the base. Replace the circuit board on the base and fixed with screw. 
 

Coverage Pattern and Dimension 

 
 

 
 

Mounting Guide 

 

 
 
 

Mount the sensor without bracket 

1. Open the front cover by loosening the locking 
    screw. 
2. Remove the PCB from the bottom case with 
care. 
3. Mount the bottom case on the wall with proper 
    knockout holes. 
4. Lead the cable into the case and replace the PCB 
   for wiring connection 

Mount the sensor with bracket 

1. Mount the base of mounting bracket on the 
    selected position as shown. 
2. Lead the cable through the central tunnel of 
    mounting bracket. 
3. Open the front cover by loosening the 
locking bolt. Lead the cable into the case and 
fix the mounting 
bracket with the bottom case of sensor. 
4.  Connect  the  cable  to  the  corresponding   
    terminals. 
 
 
 

Содержание GH-800

Страница 1: ...ance of the system please carefully read this instruction before installing Applications Benefits Resort Hotel Motel Guestrooms School College Dormitories Timeshare Vacation Units Military Lodging Fac...

Страница 2: ...c control in an aesthetically pleasing housing It should be mounted on the wall corner mount recommended to detect the presence of human by sensing the movement of body heat energy In addition to the...

Страница 3: ...e used the connection should be made in parallel GND This ground terminal normally pairs with SLA or DSW for connection of slave sensor or door switch DSW This terminal and terminal GND are for connec...

Страница 4: ...manner that it will not be damaged by hotel guest or housekeeper Mount the Sensor GH MS1 1 Remove the sensor cover by releasing the locking screw at the bottom of the housing 2 Carefully remove the c...

Страница 5: ...tallation Reflective materials mirrors shiny metal sheets marble tiles etc could reflect the infrared energy emission The sensor should be mounted at 8 ft above the floor preferably in a corner that h...

Страница 6: ...ut format Place the jumper on both pins will make the relay contact with 24V power If dry contact no load output is required remove the jumper off the pins disconnect the pins 4 Restart delay enable d...

Страница 7: ...d ensure to place the jumper JP7 to NORMAL position for normal operation of the system The normal operation of GH 800 is quite sophisticated Many different operation modes and statuses are carefully m...

Страница 8: ...nce is required The GH 800 is not field serviceable and should be returned if repair is needed field repair should not be attempted and may void warranty Be sure to include a brief description of the...

Отзывы: