Gerus GERUPRESS HP15 Скачать руководство пользователя страница 7

HP15 GERUPRESS 

Copyright by GERUS Apparatebau GmbH & Co.KG, Engelschalkstraße 16, 86316 Friedberg 

 

 

4. 

How to exchange the oil at     

           the high pressure pump 

 

 

 

Oil can be removed by opening the oi screw 

L

 and by lifting the 

pump on the opposite side of the pump. 
 
 
 

 

BE CAREFULL :    the oil starts running out as  

   soon as you have loosened  
   the screw!  
 
 
 

 

Use  oil  admission  socket 

D

 

to  fill  in  the  oil.  Oil  level  gauge 

B

 

indicates how much oil you have filled in. The pump should be 
filled up to three quarters ( ¾). 
 
 
 

 

BE CAREFULL:     Only use oils with the  
                                following specifications: 
 
 

 

oil quality: anti-corrosion oil, 

viscosity

 

approx. 13 mm² / s = cSt / 20° C 

 

 

 

 

We  advise  you  to  exchange  the  oil  every  three  years  because 
otherwise the pump might be damaged due to residues of dirt. 

 

 

 

 

 

 

 

 

 

5. 

Technical data 

 
 

Air pressure (p

B

): 

1,5 – 7,0 bar (p

Bmax 

= 15,0 bar) 

 

Output pressure (p

A

):  1500 bar (max. pressure for   

permanent operating) 

 

Test pressure (p

prüf

): 

1600 bar (test operating) 

 

Gadget connections: 

 

Output pressure 

CEJN high pressure coupling  

 

 

(type series 116) 

 

Air pressure 

compr. air conn.  

 9 mm 

Masses: 

 

empty: 

32,25 kg 

 

filled: 

38,25 kg 

Dimensions: 

 

height: 

320 mm 

 

length: 

445 mm 

 

width: 

246 mm 

 

Volume of tank: 

6 l (dm³) 

Performance and consumption of air: 

0,53 m³/min for 6 bar compr.air 

 0,37 dm³/min for 1000 bar 

1,23 m³/min for 6 bar compr.air 

 0,90 dm³/min for 0 bar 

 

 

 

 

 

 

 

 

 

6. 

After-sales  service  and  self-
help 

 

 

If  the  pressure  at  oil  pressure  gauge 

A

 

doesn’t  remain 

constant and drops (as described under point 13.), the pump 
is not air-tight. 

 

In  most  cases,  this  is  due  to  the  fact  that  the  O-rings  are 
old/worn-out.  It  is  possible  to  exchange  the  O-rings.  A 
complete  set  of  O-rings  (article-no.  11.49015-0067)  is 
enclosed in the pump. 

 

The packet of spare parts can be taken out by opening the 
front  plate 

M

.  An  explosion  drawing  of  the  pump  is  also 

included. 
It is recommendable to have the pump overhauled by its  
 

manufacturer 

 

 

GERUS APPARATEBAU GmbH & Co. KG

,  

Engelschalkstraße 16 

D-86316 Friedberg 

 

Tel.:  0049 – (0)821 – 588 662 – 0 

FAX: 0049 – (0)821 – 588 662 – 10 

E-Mail:

 

[email protected]

 

 

 

Отзывы: