Instructions 

 

The GERUPRESS provides high static pressures for using them 
in  combination  with  hydraulic  tightening  device.  Because  of  its 
specification  the  GERUPRESS  is  not  suitable  supporting  large 
delivery ranges under high pressure. Neither the capacity of the 
oil  pump  nor  the  range  of  hydraulic  oil  do  not  allow  operating 
under  these  circumstances.  In  its  specified  application,  the 
GERUPRESS  works  exclusively  with  the  medium  compressed 
air.  
The  function  of  the  GERUPRESS  is  based  on  a  proportional 
working  oil  pump.  The  absolute  maximum  output  pressure  is 
secured  by  a  security  valve  (adjustable)  in  the  low  pressure 
circle (cf. risk analysis). 
For  operating, the compressed  air  (pressure  <  15  bar)  have  to 
be  connected  to  the  GERUPRESS,  the  gauges  have  to  be 
checked and the operating lever have to be shift (operating). 
Now,  the  pump  starts  working  until  the  adjusted  value  of  the 
output pressure has been reached. 
It  is  possible  to  adjust  the  output  pressure  by  the  pressure 
limitation valve until either the requested value is pointed on the 
gauge or the maximum pressure of 1500 bar is reached. 
For set off (high pressure is no longer necessary) the operating 
lever have to be shift back in “0”-position. For ventilation of ducts 
the manual ventilation valve has to be opened. 
Disconnect  high  pressure  tubes  only  while  ventilation  valve 
open. 

 

2. 

Instructions for use 

I.

 

H

OW TO TEST A HIGH PRESSURE PUMP TO SEE 

 

    IF IT WORKS

 

  

1.)  Open the lid 
2.)  Check  if  the  pressure  gauges 

A

  and 

I

  are  intact  and        

control  the  position  of  the  indicators.  Both  indicators 
should be on zero. 

3.)  Control the oil level (by locking at oil level controller 

B

4.)  If  the  oil  level  is  too  low,  fill  in  oil  an  follow  these 

instructions: 

   4.1.  Choose the quality of the oil according to the  
           instructions on sign 

C

 

   4.2.  Open the oil admission socket 

D

 to fill in the oil by 

           turning to the left 180 degrees (180

°

).        

4.3.  Fill in the oil until the oil level controller 

B

 indicates  

that the tank has been filled up threequarters (¾). 

4.4.  Now close  the oil admission socket 

D

 by turning it to 

the right 180 degrees (180

°

).        

5.)  Close the pressure relief valve 

E

 and turn it to the right 

as far as it will go.  

6.)  Now turn lever 

F

 (=start lever) into position II. 

7.)  Connect the compressed air-tube to the compressed-air 

connection 

G

 

BE CAREFULL:    never use more than the  
                               maximum of 15 bar!              

 

8.)  Pull and turn the pressure control valve 

H

 to the right as 

far as it will go (until you feel a resistance). 

9.)  Check the air pressure on the pressure gauge 

I

 

(There 

       should be an air pressure of at least

 

 6 bar).        

10.)  Put start lever 

F

 

into position I.  

11.)  The pump starts working and should build up a pressure 

of  up  to  1.500  bar  (if  it  doesn’t,  please  check  the  air 
pressure). 

12.)  When the oil pressure gauge 

A

 

shows a pressure of  

        1.500 bar turn lever 

F

 back into position II. 

13.)  The pressure shown on oil pressure gauge 

A

 shouldn’t 

fall. This means that the pump is in working order.  

14.)  Open the relief valve 

E

 by turning it to the left. 

15.)  The pressure shown on oil pressure gauge 

A

 now drops  

         to 0 bar. 
 
 
 

 

II. How to work with the high pressure pump 

Start again with  position 2.) to 7.). 
Now  pull  and  turn  on  the  relief  valve 

H

  to  get  the  right  oil 

pressure: 
2 bar air pressure 

 500 bar oil pressure. 

Then  connect  the  high  pressure  tubes  to  the  hose 
connection 

K

Continue with position 10.) to 15.) 
 
Remove the high pressure tubes from the hose connection 

K

 

when you are finished. 

 

BE CAREFULL:    Hydraulic tubes can only be  

attached or removed if the   
relief valve E is open. The   
oil pressure gauge A has 
then dropped to 0 bar. 
 

3. 

Risk analysis 

 

a)  The  oil  pump  is  working  as  pressure  translator,  thus 

improper  output  pressures  cannot  be  reached  because 
the lower operating pressure is limited. 

b)  Improper absolute output pressures will be lock out by a 

additional  pressure  reducing  valve  in  the  low  pressure 
circle. 

c)  Leaks or duct cracks in the high pressure circle including 

no healthy risks for operators. 

d)  Duct crack cause a breakdown of the output pressure. 
e)  Is  the  determined  output  pressure  not  available  after  a 

short  time,  a  damage  of  the  GERUPRESS  is  probably 
occurred.  In  this  case,  put  the  gadget  out  of  operation, 
disconnect  the  connect  air  tubes.  Otherwise  the  gadget 
will get dirty by hydraulic oil. 

f)  Pay attention while closing of the cover. Prohibit 

 

damaging (operating level in „1“, cover  
cannot be closed) 

 

wounding 

g)  Sufficient  lubrication  of  the  oil  pump  and  providing  with 

hydraulic oil is ensured by mounting the pump into the oil 
tank.  In  case  of  a  pump  leakage,  the  gadget  and  the 
operator is protected by the casing of the tank. 

 

BE CAREFULL:  Disconnect 

high 

pressure 

tubes  only  while  ventilation 
valve open. 