Gerreka TORO-I Скачать руководство пользователя страница 2

8

Unlocking

D295J

1

Turn the cover (1).

2

Insert the key (2) and turn it clockwise without forcing it (the cylinder will
be pushed out a few millimetres by the spring).

3

Operate the handle (3) by turning it 180º to the left. The gate can now be
operated manually.

4

In order to extract the key and leave the operator unlocked, push inwards
and turn anti-clockwise.

Locking

1

Introduce the key (2) and turn clockwise without forcing it, until the
cylinder is pushed out by the spring.

2

Operate the handle (3) by turning it 180º to the right.

3

Push the key (2) in and turn it anti-clockwise (pushing it in completely in
order to turn).

4

Turn the key (2) and remove the cover (1) until the cylinder is covered.

5

Move the gate manually until interlocked in the motor.

D07K

P295Z

LB/ LR

A.T. (ST1)

COM

SG.C (FT1)

COM

A.P. (ST2)

SG.A (FT2)

AUX
(12Vdc)

FT

TO1800EIC/TO2500EIC: 230V/50-60Hz
TO1800EICM/TO2500EICM: 125V/50-60Hz

N
L
T

G1

G2
COM

60W max

(1.250/2.300W max)

M

COM

G2

G1

J7

3~

M

1~

M

J7

Pos 1

Pos 2

230V 

TO2500EIC(M)

230V 

TO1800EIC(M)

DL26

F3

F1

F21

F41

DL141

DL14

FC1

C101

: FCC

C102

: FCA

FC2

C101

: FCA

C102

: FCC

F3

General connections

(photocell 
without testing)

(photocell with testing)

(1250/2300W max)

60W max

red

white
green

brown

black

blue

Do not connect 
the capacitor in 
the motor.

F1

Primary Fuse (0.25A) 
settable*

F21

Secondary Fuse (0.9A) 
settable*

F3

Main Fuse (3A)

F41

Peripheral Fuse (0.35A) 
settable*

*

:

resets automatically when 
overload ends

DL14

LED** fuse F21

DL141

LED** fuse F41

**

:

DL ON: fuse closed; 
DL OFF: fuse open

DL26

   DC bus LED

Отзывы: