![Gerni MC 5M Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/gerni/mc-5m/mc-5m_operating-instructions-manual_2217242005.webp)
Original instruction
5
• This machine has been designed for use with the cleaning agent supplied or recommended
by the manufacturer. The use of other cleaning agents or chemicals may adversely affect the
safety of the machine
•
Risk of explosion –
Do not spray flammable liquids. Do not clean delicate parts made of rub-
ber, fabric, etc. with the jet nozzle. Keep some distance between the jet nozzle and surface in
order to prevent the surface from damage
Combustion engine powered machines:
Do not use combustion engine powered machines
indoors unless adequate ventilation is assessed by national labour authorities.
• Ensure that any exhaust emissions are not in the vicinity of air intakes
• Incorrect fuels shall not be used as they may prove hazardous.
• Do not operate belt-driven units without attached belt cover
• The machine must not be used in flammable or explosive environments. When using the ma-
chine, it must stand at least 1 m from buildings, etc.
4 Transport
For safe transport in and on vehicles we recommend to prevent the equipment from sliding and
tilting by fixing it with belts. For transport and storage at temperatures around or below 0°C,
anti-freeze should be drawn into the pump beforehand (Please refer to Operating Instructions).
5 Water connection
If the machine don´t have a watertank, the machine is only allowed to be connected
with the potable water mains, when an appropriate backflow preventer has been installed, Type
BA, according to EN 60335-2-79. The backflow preventer can be ordered thought Gerni Ser-
vicecenter. The length of the hose between the backflow preventer and the machine must be at
least 12 meters (min diameter 3/4 inch) to absorb possible pressure peaks. Operation by suc-
tion (for example from a rainwater vessel) is carried out without backflow preventer. The suction
set can be ordered thought Gerni Servicecenter.
WARNING!
Water that has flowed through backflow preventer and high pressure washer
is considered to be non-potable.
6 Electrical connection
The connection of the electrical supply must be performed by an qualified electrician
and comply with IEC 60364-1. The earth wire must be connected to correct potential and it is
recommended that the electric supply to this machine should include either a residual current
device or another device that will protect the user against indirect contact. The electrical instal-
lation to the machine must be according to local regulations.
WARNING!
Inadequate extension cords can be dangerous. If an extension cord is used, it
shall be suitable for outdoor use, and the connection plug has to be kept dry and off the ground.
It is recommended that this is accomplished by means of a cord reel, which keeps the socket at
least 60mm above the ground. Always unwind cord from the reels completely to prevent the
power cord overheating. Disconnect the power cord from the power source by pulling the plug
only (do not pull or tug the power cord).