![Gerni MC 5M Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/gerni/mc-5m/mc-5m_operating-instructions-manual_2217242025.webp)
25
1)
Options / model variants
Original instructions
MC 5M - MC 6P - MC 7P
8 Troubleshooting
Fault
Cause
Remedy
Pressure drop
•
Air in the system
• Vent the system by
operating the spray gun
several times at short
intervals. If necessary,
operate the cleaner for a
short time without the high-
pressure hose connected.
• High pressure nozzle blocked
worn
• Clean/replace the high
pressure nozzle
•
Detergent tank empty
•
Top up detergent tank or
set detergent to “0”
Pressure
fl
uctuations
•
Pump draws in air (only
possible in suction mode)
•
Check that the suction set
is air-tight
•
Lack of water
•
Open water tap
•
Water inlet hose is too long
or its cross-section too small
•
Use a water inlet hose
that can provide the water
fl
ow (Q
max
) de
fi
ned for the
machine
•
Lack of water caused by
blocked water
fi
lter
•
Clean the water
fi
lter in the
water connection (never
work without water
fi
lter)
•
Lack of water because max.
permissible suction height
has not been heeded
•
See instructions
The motor does not start when
the cleaner is switched on
•
•
The plug is not inserted
properly, i.e. there is no
current
Oil level too low
•
•
Check the plug, lead and
switch and if necessary
have them replaced by a
skilled electrician
Check oil/add oil
•
•
The mains fuse is switched
off
The overload protection
has been activated due to
overheating or overloading of
the motor
•
•
Switch on the mains fuse
Check that the mains
voltage and the cleaner
voltage are the same.
Switch off the cleaner and
allow it to cool for at least 3
minutes
When the cleaner is switched
on the motor buzzes without
starting
•
The mains voltage is too low
or there is a phase failure.
•
Have the electrical
connection checked
•
The pump is blocked or
frozen
•
Contact the Gerni customer
service
•
Incorrect cross-section or
length of the extension lead
•
Use lead with correct cross
section or length
The motor switches off
•
The overload protection
has been activated due to
overheating or overloading of
the motor
•
Check that the mains
voltage and the cleaner
voltage are the same.
Switch off the cleaner and
allow it to cool for at least 3
minutes
•
High-pressure nozzle is dirty
•
Change the high-pressure
nozzle