Install indoor unit 

m

m

0

5

1

φ55mm or φ65mm

φ55mm or φ65mm

m

m

0

5

1

Ø55
or Ø

65 

Install the rear panel 

1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the

both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is 

taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and 

level should be 0 or more, that is good for condensing water drainage. 

2.Fix the rear panel on the wall with screws.
(Where is pre-covered with plastic granula) 

3.Be sure that the rear panel has been fixed
firmly enough to withstand the weight of an 

adult of 60kg, further more, the weight should 

be evenly shared by each screw.

Install the piping hole 

1.Make the piping hole (Ф55 or Ф65) in the wall at a sl

ight downward slant to

   the outdoor side.

2.Insert the piping-hole sleeve into the hole to prevent the connection piping
   and wiring from being damaged when passing through the hole. 

Install the water drainage pipe 

1.For well draining, the drain hose should be placed at a downward slant. 

2.Do not wrench or bend the drain hose or flood its end by water.

3.When the long drainage hose passing through indoor,
   should wrap the insulation materials. 

Wrenched

Bent

Flooded

Indoor

Outdoor

Wall pipe 

Seal pad 

Fig.5

Wall

Wall

Mark on the middle of it 

Gradienter

Left

Right

(Rear piping hole) 

(Rear piping hole) 

Space
to the
wall

above

Space
to the
wall

above

Connect indoor and outdoor electric wires 

1.Open the surface panel.
2.Remove the wiring

cover Fig.6.

3.

Route the power connection cord and signal control w ire (for cool ing and heating unit only ) from the

4

.Connect the inter connection cord to the terminal block, and then f ix the cord w ith cord anchorge.

5

.Reassemble the clampand wiring cover.

back of the indoor unit and pull it toward the front through the wiring hole for connection.

6

.

Recover the surface panel .

yellow-

green

violet

09

05

07

12K Cool and Heat 

05

07

09

12K

violet

brown

yellow-

green

yellow-

green

yellow-

green

yellow-

green

18K Cool and Heat type

(for some model)

18K Cool only type

yellow-

green

(for some model)

18K Cool only type

violet

brown

yellow-

green

24K Cool and Heat type

Fig.6

14K

Cool only type 

type 

24K Cool only type 

Содержание SC-09

Страница 1: ...SC 09 SC 12 Please read these instructions and warranty information carefully before use and keep them handy for future reference With Remote Control MODE ON OFF FAN CLOCK BLOW TURBO SLEEP LIGHT TEMP...

Страница 2: ......

Страница 3: ...this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary The products in this manual may be different with the real one according to different m...

Страница 4: ......

Страница 5: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Страница 6: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Страница 7: ...ty will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat exchanger when indoor heat exchanger tempe...

Страница 8: ...e range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdoor sideDB WB o C 32 23 21 15 27 20 43 26 21 24 18 5 6 Working temperature range Maximum cooling Minimu...

Страница 9: ...r unit Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable Remote control Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Cool Dry Fan Heat...

Страница 10: ...tion is canceled After Sleep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available Press this button A...

Страница 11: ...ontroller it could be used for the air conditioners TEMP button TEMP Press this button could select displaying the indoor setting temperature or indoor ambient temperature When the indoor unit firstly...

Страница 12: ...ased 1 minute Hold pressing or button 2 seconds later it quickly change the way of change is During the initial 2 5 seconds ten numbers change in the one place of minute then the one place is constant...

Страница 13: ...button to set sleep 2 Press TIMER ON and TIMER OFF button can set the scheduled timer on 3 Press LIGHT button to control the on and off of the displaying part of the unit This function may be not ava...

Страница 14: ...wireless remote control 1 Changing batteries and notices 10 4 2 3 Slightly to press the place with along the arrowhead direction to push the back cover of wireless remote control As show in figure Tak...

Страница 15: ...light off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this s...

Страница 16: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Страница 17: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Страница 18: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Страница 19: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Страница 20: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Страница 21: ...authorized Maintenance Center in the local area Notices for installation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is un...

Страница 22: ...ons of magnetic tripping and heat tripping in order to protect the short circuit and overloading 6 Notices for installation Safety Requirements For Electric Appliances 1 Select a location from which n...

Страница 23: ...able earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other places that professional personnel consider them unreliable 5 In...

Страница 24: ...ll Space to the wall Air outlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above e v o b A The dimensions of...

Страница 25: ...e pipe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor sho...

Страница 26: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Страница 27: ...handle on the outdoor unit right side plate Take off cord anchorage Connect and fix power connect cord for cooling and heating unit connect and fix power connect cord and signal control wire to termi...

Страница 28: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Страница 29: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Страница 30: ......

Страница 31: ...SC 09 SC 12...

Страница 32: ...SC SERIES M 11 1 66129908344...

Отзывы: