German pool SC-09 Скачать руководство пользователя страница 13

Operation of wireless remote control

This function indicates that moisture on evaporator of indoor unit will be blowed after the unit 

About 

X-FAN

 function

is stopped to avoid mould.

1. Having set 

X-FAN

 function on: After turning off the unit by pressing ON/OFF button indoor

fan will continue running for about 10 min. at low speed. In this period,  press 

X-FAN

 button

  to stop indoor fan directly.

2. Having set 

X-FAN

 function off: After turning off the unit by pressing ON/OFF button, the

  complete unit will be off directly.

Introduction for special function 

1. After powered on, press ON/OFF button, the unit will start to run.(Note: When

it is powered on, the guide louver of main unit will close automatically.)

2. Press MODE button, select desired running mode.

 

3. Pror - button, to set the desired temperature. (It is unnecessary

to set the temp. at AUTO mode.)

4. Pressing FAN button, set fan speed, can select AUTO FAN, LOW, MID 

and HIGH.

5. Pressing 

 button, to select the swing.

1. Press SLEEP button, to set sleep.

2. Press TIMER ON and TIMER OFF button, can set the scheduled timer on 

3. Press LIGHT button, to control the on and off of the displaying part of the 

unit (This function may be not available for some units).

4. Press TURBO button, can realize the ON and OFF of TURBO function.

or timer off.

Guide for operation-  General operation

Guide for operation- Optional operation

When AUTO RUN mode is selected, the setting temperature will not be displayed on the 
LCD, the unit will be in accordance  with the room temp. automatically to select the suitable 
running method and to make ambient comfortable.

About turbo function

If start this function, the unit will run at super-high fan speed to cool or heat quickly  so that
the ambient temp. approachs the preset temp. as soon as possible.

About AUTO RUN

9

When the unit is running in Heat mode or Auto Heat mode, compressor and indoor fan is running,
to turn the unit off, the compressor, outdoor fan will stop running. The upper and lower guide board
rotate to horizontal position, then the indoor fan will run at low fan speed, 10s later, the unit will turn off.

About

Blow 

over heat (This function is applicable to partial of models)

Содержание SC-09

Страница 1: ...SC 09 SC 12 Please read these instructions and warranty information carefully before use and keep them handy for future reference With Remote Control MODE ON OFF FAN CLOCK BLOW TURBO SLEEP LIGHT TEMP...

Страница 2: ......

Страница 3: ...this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary The products in this manual may be different with the real one according to different m...

Страница 4: ......

Страница 5: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Страница 6: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Страница 7: ...ty will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat exchanger when indoor heat exchanger tempe...

Страница 8: ...e range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdoor sideDB WB o C 32 23 21 15 27 20 43 26 21 24 18 5 6 Working temperature range Maximum cooling Minimu...

Страница 9: ...r unit Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable Remote control Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Cool Dry Fan Heat...

Страница 10: ...tion is canceled After Sleep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available Press this button A...

Страница 11: ...ontroller it could be used for the air conditioners TEMP button TEMP Press this button could select displaying the indoor setting temperature or indoor ambient temperature When the indoor unit firstly...

Страница 12: ...ased 1 minute Hold pressing or button 2 seconds later it quickly change the way of change is During the initial 2 5 seconds ten numbers change in the one place of minute then the one place is constant...

Страница 13: ...button to set sleep 2 Press TIMER ON and TIMER OFF button can set the scheduled timer on 3 Press LIGHT button to control the on and off of the displaying part of the unit This function may be not ava...

Страница 14: ...wireless remote control 1 Changing batteries and notices 10 4 2 3 Slightly to press the place with along the arrowhead direction to push the back cover of wireless remote control As show in figure Tak...

Страница 15: ...light off If cancel the light function the mark will disap per on the remote controller screen by pressing this button In which case the displayer indicator light will be off if the AC receives this s...

Страница 16: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Страница 17: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Страница 18: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Страница 19: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Страница 20: ...ash water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very...

Страница 21: ...authorized Maintenance Center in the local area Notices for installation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is un...

Страница 22: ...ons of magnetic tripping and heat tripping in order to protect the short circuit and overloading 6 Notices for installation Safety Requirements For Electric Appliances 1 Select a location from which n...

Страница 23: ...able earthing terminal Please don t connect the earthing wire with the following place Tap water pipe Gas pipe Contamination pipe Other places that professional personnel consider them unreliable 5 In...

Страница 24: ...ll Space to the wall Air outlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above e v o b A The dimensions of...

Страница 25: ...e pipe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor sho...

Страница 26: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Страница 27: ...handle on the outdoor unit right side plate Take off cord anchorage Connect and fix power connect cord for cooling and heating unit connect and fix power connect cord and signal control wire to termi...

Страница 28: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Страница 29: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Страница 30: ......

Страница 31: ...SC 09 SC 12...

Страница 32: ...SC SERIES M 11 1 66129908344...

Отзывы: