German pool HTB-248U Скачать руководство пользователя страница 12

P.12

Functions

Ventilation Function     

• 

Press “VENT 

” 

button, the “VENT

 

indication light gets on, air volume will at the “Low 

Speed  ”. Press the “SPEED  ” button to inter-change to the “High Speed  ” or  “Low Speed 

” mode.

• 

Timer: The default setting is 2 hours, can change the length of the duration by pressing the “+” 

or “-” of the “TIMER” button. The time could be set from 1 hour to 24 hours. The remaining time 

will be showed on the 

 LED display. The time selection will be recorded in memory when the 

machine is off, and will resume in next usage.

• 

Stop: Press the “STOP  ” button or when pre-set time is over, “VENT 

” indication light gets 

off, the remaining time display will also be off, and the machine stops automatically.

 

 

       

24 Hours Ventilation Function 

• 

Start: Press “24HR VENT. 

 

button,the “VENT 

 

indication light gets on, 24 hours 

ventilation will run in “Low Speed  ” mode. It is not changeable. The default stop will take effect 

after 24 hours. Time cannot be changed. The remaining time will be showed on the 

 LED 

display.

• 

Stop: Press the“24HR VENT. 

” button once again and the machine will stop automatically 

after the operation, “VENT. 

 

indication light also gets off automatically. “STOP  ” button is 

invalid during Vent 24HRS function.

• 

When “24HR VENT. 

” function is running, users can press any function keys to perform a 

preferred function. After the preferred function is completed, the machine will resume the “24HR 

VENT. 

” function, from where it left behind. The machine will count the 24 hours from the 

original start time including the time spent on inserting the preferred function. When the time is 

up for an accumulative total of 24 hours, the machine will stop automatically.

Delay Off Function 

MIN

15

 

• 

Start: Press “DELAY OFF 

MIN

15

 

” button, “VENT 

 ” indication light turns on, the product turns 

on, air outlet vent closes, sucking the indoor air outside, acting like an exhaust fan. Indicating 

“Delay Off” function is in operation. After 15 minutes, product will automatically stop. Time is not 

adjustable, and not indicated on the LED display.

• 

This function runs in default “Low Speed” and wind speed is not adjustable.

• 

Stop: Press “STOP   ” button to cancel function; or product automatically stops after default 

time is up. 

UVC Sterilization Function 

 

• 

Start: When product is turned on, press “UVC 

 ” button, 

 indication light gets on, UVC 

sterilization commences and will automatically stop after 1 hour.

• 

Stop: When UVC sterilization is in progress, press “UVC 

 ” button, UVC sterilization function 

stops, and 

 indication light turns off.

Note:

• 

During “24HR VENT. 

” operation, press any other function button, the machine will shift to 

operate the latest selected function. The “Vent 24HRS” will continue to run after the latest selected 

function is finished. The timer will accumulate the time spent on other selected functions during the 

period, and will stop automatically after 24 hours.

• 

Functions that can be performed during “24HR VENT. 

” operation do not include “Ventilation 

Function” and “Delay Ventilation” function.

Содержание HTB-248U

Страница 1: ...ine Warranty Registration HTB 248U Multi Purpose UVC Bathroom Heater Please read these instructions and warranty information carefully before use and keep them handy for future reference U S E R M A N...

Страница 2: ...P 2 Please register your warranty information now For Warranty Terms Conditions please refer to the last page of this user manual...

Страница 3: ...3 Table of Contents Warnings Safety Precautions 04 Product Structure 07 Installation 08 Functions 11 Cleaning Maintenance 16 Troubleshooting 17 Technical Specification 17 Warranty Terms Conditions 31...

Страница 4: ...avoid danger Must carried out in accordance with the safety requirements of the unit installation electrical wiring by professionals Modifying the product is banned otherwise it may lead to damage of...

Страница 5: ...operly Please correctly install the product in order to avoid the abnormal noise when it is used Please use this product under rated requirements Please set airflow intake to promote convection If ins...

Страница 6: ...eater than the no 8 signal there may be water coming through the product framework into the bathroom This appliance contains a UV emitter DO NOT stare at the light source Do not look directly into the...

Страница 7: ...P 7 Product Structure Wireless Remote Control Main Body Air Filter Main Body Receiver Air Louver Front Panel Display...

Страница 8: ...OM REMOTE CONTROL SIDE Product Dimension Unit mm Packaging Accessories List Purpose Fix the Remote Control Fix the Body Outlet interface Product Description Screw Screw Screw Plastic plug Specificatio...

Страница 9: ...er Aluminum window About 2300 mm off the ground Note This product is suitable for window installation For wall or ceiling installation an additional air outlet fitting needs to be purchased separately...

Страница 10: ...r onto its designated spot and mark the screw hole according to the arrow in the diagram 2 Drill a 6mm hole on the marked spot insert a plastic plug then screw on the holder 3 Place the remote control...

Страница 11: ...op Press the STOP button or when pre set time is over WARM indication light gets off the remaining time display will also be off and the machine stops automatically When the heater stops running the f...

Страница 12: ...VENT function from where it left behind The machine will count the 24 hours from the original start time including the time spent on inserting the preferred function When the time is up for an accumu...

Страница 13: ...ime will be showed on the LED display The time selection will be recorded in memory when the machine is off and will resume in your next usage Stop STOP button or when pre set time is over the machine...

Страница 14: ...n light gets on and the machine starts to run in automatic mode and the air volume runs at the mode of Low Speed After 20 seconds the machine will run at different modes according to the current room...

Страница 15: ...r can only turn off the machine manually After turning off manually the fault code will be erased If the temperature dropped below 65 PTC will recover and be turned on automatically the fan gear set w...

Страница 16: ...ent Wipe again with another wet cloth to ensure there is no detergent residues Cleaning the Filter Please take out the filter and put it in water to clean the dust and dirty after around 1 months usua...

Страница 17: ...ication Specifications are subject to change without prior notice If there is any inconsistency or ambiguity between the English version and the Chinese version the English version shall prevail Refer...

Страница 18: ...P 18 19 21 23 25 29 30 30 31...

Страница 19: ...P 19 3 3 8...

Страница 20: ...P 20 2 3m 2 240mm h 8 1 2 5 3mm 250V 13A...

Страница 21: ...P 21...

Страница 22: ...P 22 51 7 216 234 255 213 23 165 55 35 225 19 255 205 97 84 5 53 33 5 7 5 ST3 9 25 7 ST3 9 25 7 ST4 2 25 9 6 28 2 3 4 2...

Страница 23: ...P 23 254mm X 254mm 219mm X 209mm 1 2 2 3...

Страница 24: ...P 24 1 2 6mm 3...

Страница 25: ...P 25 2 1 24 25 PTC 2 1 24 UV 15 24...

Страница 26: ...P 26 24 24 24 24 24 24 24 24 MIN 15 MIN 15 15 UVC UVC UVC 1 UVC UVC 4 1 24 PTC 25 PTC 2 1 24...

Страница 27: ...P 27 20 20 1 10 24 2 10 20 PTC 3 10 20 24 PTC 4 1 5 30 PTC 2 2 25 PTC 1 PTC 2 1 50 PTC 4 1 24 60 90 90...

Страница 28: ...P 28 1 5 2 PTC 5 PTC 3 PTC 3 1 2 3 PTC 2 2 50 55 PTC 40 PTC 50 55 2 3 55 PTC 2 4 40 40 PTC 3 1 PTC 80 PTC 3 2 PTC 80 90 PTC 65 PTC 80 90 3 3 90 PTC 3 4 65 65 PTC...

Страница 29: ...P 29...

Страница 30: ...P 30 www germanpool com HTB 248U 220 240V 50Hz 1 400W H 255mm W 255mm D 225mm 4 5kg...

Страница 31: ...ion repair or replace any defective part 5 This warranty will be void if there is any transfer of ownership from the original purchaser 1 2 3 4 5 Serial No Purchased From Invoice No Purchase Date Mode...

Страница 32: ...Fax 86 757 2219 6809 8th Xinxiang Road Wusha Industrial Park Daliang Shunde Foshan Guangdong 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 853 2875 2699 Fax 853 2875 2...

Отзывы: