P.12
P.13
4. Use
40
30
25
20
10
0
.0,0
1,0
2,0
Hot water output [l/min]
Te
m
per
atu
re
incre
ase
[K]
3,0
4,0
5,0
5,7kw
4.2 Adjusting the water flow and temperature
May only be carried out by a specialist.
Remove the cover, undo the hood screw underneath and remove the hood.
Decreasing the flow rate:
Turn the adjusting screw clockwise to decrease the flow rate, thus making a higher
outlet temperature possible.
Increasing the flow rate:
Turn the adjusting screw counter-clockwise to increase the flow rate, thus reducing
the possible outlet temperature.
Direction of rotation
Flow
Temperature
4.1.2 Replacing the cover
1. Push the cover flat towards the wall bracket under the edges of the water connections.
2. Press down the front edge of the cover and push it forward again at the rear edge until it fits.
3.5 Initial start-up
Do not switch on the electric power at this time!
1. To purge the instantaneous water heater, open the hot water tap and wait until the water emerges free
of air bubbles.
2. Switch on the electric power.
3. Adapt the water flow if necessary, if for example the temperature is not reached. The procedure is
described in the chapter “Use”.
4. Explain the functions and use of the instantaneous electric water heater to the user and hand over this
User Manual to the user for information and future reference.
As soon as the hot water tap is opened, the instantaneous water heater switches on automatically. Close the
tap and the appliance switches off automatically again.
4.1 Rating plate cover
On the inner part of the cover you can find the name of the application type (1), as well as the serial number
(2) and the article number (3).
4.1.1 Removing the cove
r
Under this cover, the rating plate and the hood screw are located.
1. Push the cover at the corrugation towards the wall bracket.
2. At the rear corners press the cover down until the front edge lifts.
3. Remove the cover by pulling forward.
3.Installation
4. Use
1
2
AAAA
Gerät an Schutzleiter
anschließen!
Appliance must be earthed!
BBBB
CCCC
3