background image

 

(

(

4

4

x

x

3

3

6

6

 

 

W

W

a

a

t

t

t

t

)

)

 

 

GLP 

 German Light Products GmbH

 

 

Version 

1.1

 5 

2  Preparation and Installation 

2.1 Mounting 

The 

 can be mounted in any arbitrary position without any gaps. To 

ensure a safe installation under all circumstances, the system offers various 

possibilities like screw-on standings and assembly angle, different attaching by 

means of a hook, classical M10 hook or CAMLOC quick-lock-systems. 

835

640

770

4x M10

700

82

 

2.2 Secure 

the 

 

Regardless of the rigging of the 

 you have to use a stipulated safety 

wire. Therefore you have to thread a safety wire through the intended application at 

the fixture and connect it with the truss-support. Pay attention to a safe and proper 

fastening. 

 

Pay attention to the regulations of: BGV C1 (former VBG 70) and 

DIN VDE 0711-217 ! 

The installation should be done by qualified staff only. 

2.3 Connections 

You can connect up to 15 

 in one row. The 

 

S

S

p

p

l

l

i

i

t

t

t

t

e

e

r

r

 is 

therefore connected to a single 16A phase. Also the DMX signal for all 15 

 is attached directly to this device. Power and the DMX signal will be 

both transmitted over the multi-core cable, connected firmly with the system. For 

forwarding the power and DMX signal, differently manufactured cables are available 

as accessories. 

During mounting and dismounting, the system must be disconnected 

from the mains supply. Otherwise the connectors can by damaged!  

 

Содержание Startube 4 HiRes

Страница 1: ...1 12 20 0c cm m 4 4x x3 36 6 W Wa at tt t i in nc cl l S Sp pl li it tt te er r Instruction Manual from software version 4 1 Instruction version 1 1 Email service glp de Internet http www glp de ...

Страница 2: ...tions 4 2 Preparation and Installation 5 2 1 Mounting 5 2 2 Secure the 5 2 3 Connections 5 2 4 Adjust the DMX Address 6 2 5 Channel configuration and operation mode 7 2 6 DMX Table 7 3 Operating 7 4 Maintenance Tube change 8 5 Technical Specification 8 5 1 Startube 4 HiRes 8 5 2 Assembly and dimensions 9 5 3 General view 9 5 4 Accessory Splitter 10 ...

Страница 3: ...wo dimmer curves to turn on a stroboscope effect and to regulate the maximum brightness of all tubes The DMX start address is adjusted simply over keys at the system and directly indicated over the display In Seven Channel Mode the Display goes out 10 seconds after the last key press to enable operation in darker settings The mode switchover takes place by pushing two keys of the Display simultane...

Страница 4: ...n authorized specialist dealer or directly to G GL LP P 2 The is exclusively meant for the use in the internal area Never use or store the system out of doors 3 When installation the devices attention is to be paid to a sufficient temperature heat sink Take advised from the G GL LP P support if an installation in restrained or badly ventilated conditions is planned 4 Protect the equipment against ...

Страница 5: ...nded application at the fixture and connect it with the truss support Pay attention to a safe and proper fastening Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation should be done by qualified staff only 2 3 Connections You can connect up to 15 in one row The S Sp pl li it tt te er r is therefore connected to a single 16A phase Also the DMX signal for a...

Страница 6: ... Key 1 for the 1 digits Counting upwards Each unit uses four or seven DMX channels Channel 1 white in Seven channel mode Channel 2 red Channel 5 pre heating off dimmer curve selectable Channel 3 green Channel 6 Stroboscope effect Channel 4 blue Channel 7 superior dimmer Example In Four channel mode In Seven channel mode no 1 DMX Channel 001 DMX Channel 001 no 2 DMX Channel 005 DMX Channel 008 no 3...

Страница 7: ...ings of channel 1 4 2 6 DMX Table Channel 1 Brightness of the first tube in 255 steps Channel 2 Brightness of the second tube in 255 steps Channel 3 Brightness of the third tube in 255 steps Channel 4 Brightness of the fourth tube in 255 steps In Seven channel mode Channel 5 0 99 linear dimmer curve 100 199 dimmer curve softer in lower sector 200 255 pre heating of the tubes off Channel 6 0 15 tub...

Страница 8: ...arrow band leather around the tube ends and slue it around carefully If the vertical slot of the socket is visible the tube can be then removed Insert the tube in reverse order again New tubes should be operated approx 100 hours for reaching an optimal operational behavior on full efficiency Only fluorescent tubes of the type T8 36W must be used 5 Technical Specification 5 1 Startube 4 HiRes Power...

Страница 9: ... 4 4x x3 36 6 W Wa at tt t GLP German Light Products GmbH Version 1 1 9 5 2 Assembly and dimensions 1237 835 640 770 4x M10 700 1302 130 93 82 161 5 3 General view A A B B ...

Страница 10: ... 4 4x x3 36 6 W Wa at tt t 10 Version 1 1 GLP German Light Products GmbH 5 4 Accessory Splitter ...

Страница 11: ... 4 4x x3 36 6 W Wa at tt t GLP German Light Products GmbH Version 1 1 11 ...

Отзывы: