German Light Products®
KNV User Manual Rev. 1.0
15
To obtain synchronized chases in multiple fixtures you must set up FX Length and FX
Offset parameters in combination. Here is how FX Length and FX Offset work in a single
fixture:
•
FX Length = Off (DMX value zero on the
FX Length
DMX channel): The FX pattern will
have the normal length of five pixels. It will start at pixel 1, run from pixel 1 to pixel 5
and then immediately start at pixel 1 again.
•
FX Length = 30 (DMX value 030 on the
FX Length
DMX channel): The FX pattern will
start at pixel 1, run from pixel 1 to pixel 5 and then black out for the time it takes to
run the FX pattern on pixels 6 – 30.
•
FX Offset = Off (DMX value zero on the
FX Offset
DMX channel): The FX pattern will
start at pixel 1.
•
FX Offset = 6 (DMX value 006 on the
FX Offset
DMX channel): The FX pattern will start
at pixel 6. If you have set an FX length of 30, the pixels will black out for the time it
takes to run the FX pattern on pixels 1 – 5, then run the FX pattern on pixels 6 – 10,
then black out for the time it takes to run the FX pattern on pixels 11 – 30.
To create a single FX pattern chase that will run across an array of multiple fixtures, you
need to:
•
Set FX Length in all the fixtures to the total number of pixels that the pattern will run
across, and
•
Set FX Offset in each fixture in a sequence five pixels apart.
This means that, if you want an FX pattern to run across six fixtures in a horizontal row
and return immediately to pixel 1 when it reaches pixel 30 at the end of the row, you
must set FX Length to 30 on all six fixtures and set FX Offsets with a gap of five pixels
between fixtures. To give a concrete example, here is how you must set up each
fixture:
•
Fixture 1: FX Length = 30, FX Offset = 1
FX will start at Pixel 1 of the 30 pixels in FX Length and run on pixels 1 - 5
•
Fixture 2: FX Length = 30, FX Offset = 6
FX will start at Pixel 6 of the 30 pixels in FX Length and run on pixels 6 - 10
•
Fixture 3: FX Length = 30, FX Offset = 11
FX will start at Pixel 11 of the 30 pixels in FX Length and run on pixels 11 – 15
•
Fixture 4: FX Length = 30, FX Offset = 16
FX will start at Pixel 16 of the 30 pixels in FX Length and run on pixels 16 - 20
•
Fixture 5: FX Length = 30, FX Offset = 21
FX will start at Pixel 21 of the 30 pixels in FX Length and run on pixels 21 - 25
•
Fixture 6: FX Length = 30, FX Offset = 26
FX will start at Pixel 26 of the 30 pixels in FX Length and run on pixels 26 - 30