background image

 

 

GLP 

 German Light Production 

(V1.11)

 

21

 

Position 

Interval 

In this way 

Outside optic 

weekly 

soft cloth and glass cleaning fluid 

Color filter 

monthly 

soft cloth and glass cleaning fluid 

Gobos 

yearly 

vacuum cleaner, airbrush, etc. 

Glass gobos 

monthly 

soft cloth and glass cleaning fluid 

Prism 

monthly 

soft cloth and glass cleaning fluid 

Dimmer/Shutter 

yearly 

vacuum cleaner, airbrush, etc. 

Inside lens 

monthly 

soft cloth no glass cleaning fluid 

Fan and air channel 

monthly 

vacuum cleaner, airbrush, etc. 

Reflector 

never 

 

Lamp 

never 

 

Moveable parts 

yearly 

suitable fatty oil 

 

Attention: 

1. Never let optical parts come into contact with oil or grease. 

2. Wait until all parts are dried up before operating the fixture. 

 

6.3  Cleaning the Optical System 

1.  Pull out the main plug! 

2.  Wait at least 20 minutes after the last operation to cool down the fixture. 

3.  Remove the Roto Head by loosening the 6 head-screws.  

4.  Remove the inside optical plug-in by loosening the two hexagon socket screws 

and pull it out. 

5.  Clean all glasses, lenses and mirrors carefully. 

6.  Before you put the 

M

M

I

I

N

N

I

I

 

 

P

P

A

A

T

T

E

E

N

N

D

D into operation close the casing, otherwise 

your retina can be hurt! 

 

 

Содержание Mini Patend

Страница 1: ...Instruction Manual from software version 1 07 instruction version 1 11 e mail service glp de Internet http www GLP de ...

Страница 2: ...GLP German Light Production V1 11 2 ...

Страница 3: ...Audio Program AUDI 11 3 4 Lamp On Off LAMP 12 3 5 Reset RESE 12 3 6 Running time of lamp and unit TIME 12 3 7 Invert Pan Movement RPAN 12 3 8 Invert Tilt Movement RTLT 12 3 9 Special Functions SPEC 13 3 9 1 Manual Drive MANU 13 3 9 2 Lamp On automatically LAAU 13 3 9 3 Lamp Off via DMX DLOF 14 3 9 4 DMX Input DMXI 14 3 9 5 Display DISP 14 3 9 6 Adjustments and Calibrations ADJU 15 3 9 7 Default Se...

Страница 4: ...5 3 Lamp adjustment 19 6 Maintenance and Cleaning the M MI IN NI I P PA AT TE EN ND D 20 6 1 Safety Regulations 20 6 2 Circumference and Interval rule of thumb 20 6 3 Cleaning the Optical System 21 7 Technical Specification 22 8 Index 23 ...

Страница 5: ...r 3 Base 4 Carrying handles 5 Connections 1 Mode button 2 Enter button 3 Up button 4 Down button 5 Microphone 6 Microphone Sensitivity 7 Software Update connector 8 DMX Input 9 DMX Output 10 Fan air inlet 11 Power On Off 12 Fuses 13 LED Display 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Страница 6: ...fore you open the M MI IN NI I P PA AT TE EN ND D Please do not touch the bulb of the lamp if you are not absolutely sure it is cold Danger of BURNING 5 Never look directly into the beam of the lamp You risk injury of your retina and blindness 6 Pay attention of the maximum lamp operation time You have to change it if the lamp shows any deformations or damages The same is with all glass components...

Страница 7: ...le materials decoration etc Install a safety wire that can hold at least 10 times the weight of the fixture Never use the carrying handles for secondary attachment Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation should be done by qualified staff only 2 1 1 Clamps Use two clamps on the backside of the M MI IN NI I P PA AT TE EN ND D to mount the unit o...

Страница 8: ...lates are included in the delivery 2 2 Secure the M MI IN NI I P PA AT TE EN ND D Regardless of the rigging of the M MI IN NI I P PA AT TE EN ND D you have to use a stipulated safety wire Therefore you have to thread two safety wires through to two provided holes on the backside of the fixture and connect it with the truss support Pay attention to a safe and proper fastening The mounting plates wi...

Страница 9: ...nput output See also printing on the case for the right pin assignment Pin 3 Pin 2 Ground Pin 1 The DMX Addressing starts at the DMX Address 001 2 4 Fuse The M MI IN NI I P PA AT TE EN ND D electronic system is protected by two live and neutral 5x20 mm fuses 230V T 2A EU model or 115V T 3 15A US model Please see the printing on the M MI IN NI I P PA AT TE EN ND D for more details Attention Disconn...

Страница 10: ...nning audio program slow AFST Self running audio program fast MSTR Master for the audio program LAMP Switch on off the lamp direct at the M MI IN NI I P PA AT TE EN ND D RESE Reset TIME POWR Running time of the fixture no destructible LA1 Running time of the lamp erasable LA2 Running time of the lamp no destructible RPAN Reverse Pan direction RTLT Reverse Tilt direction SPEC MANU Manual drive of a...

Страница 11: ...etting by pressing the Enter key the display shows OK or press the Mode key to cancel The DMX address is stored also while switching off the M MI IN NI I P PA AT TE EN ND D 3 2 The Test Program TEST test The Test Program allows you to run a complete self test procedure of all functions Press Enter to confirm or Mode to cancel 3 3 The Audio Program AUDI Audi The Audio menu allows you to run a stand...

Страница 12: ...unit TIME TIME By this option can read out three different running times of the fixture POWR Running time of the fixture no destructible LA 1 Running time of the lamp erasable Push the Up Down keys at one time to delete this running time LA 2 Running time of the lamp no destructible 3 7 Invert Pan Movement RPAN RPAN This function allows you to invert the Pan movement Use the Up Down keys to select...

Страница 13: ...osition RPAN 000 255 Pan Rotation RTLT 000 255 Tilt Rotation COLO 000 255 Color wheel GOBO 000 255 Gobo wheel SHUT 000 255 Dimmer Shutter Strobe function the lamp strikes at DMX 255 FOCU 000 255 Focus SPED 000 255 Speed Pan Tilt SPEC 000 255 Lamp Off Reset 3 9 2 Lamp On automatically LAAU LAAU This function enables you to switch ON the lamp automatically after switching ON the fixture Use the Up D...

Страница 14: ...ixture Use the Up Down keys to select desired channel and press Enter to read its value Function Value Remark PAN 0 255 Pan Position TILT 0 255 Tilt Position RPAN 0 255 Pan Rotation RTLT 0 255 Tilt Rotation COLO 0 255 Color wheel GOBO 0 255 Gobo wheel SHUT 0 255 Dimmer Shutter Strobe function FOCU 0 255 Focus SPED 0 255 Speed Pan Tilt MOVE 0 255 Movement SPEC 0 255 Lamp Off Reset 3 9 5 Display DIS...

Страница 15: ... more with the Enter key or cancel with the Mode key Function Value Remark COLO 99 99 Color wheel GOBO 99 99 Gobo wheel SHTR 01 01 Shutter ARES To initiate a reset for adjustment of the Shutter Unit must be turned off and on afterwards clre Adjustments in the internal circuit 3 9 7 Default Settings DFSE DFSE Press Enter to reset all fixture personalities not the adjusted functions to the default v...

Страница 16: ...0 FF 50 100 static positioning with channel 3 and 4 0 1 0 1 1 CW slow fast 2 127 2 7F 2 49 6 Tilt Rotation CCW fast slow 128 255 80 FF 50 100 open 0 1 00 01 0 2 open color 1 2 3 02 03 1 0 color 1 4 5 04 05 1 8 color 1 color 2 6 7 06 07 2 5 color 2 8 9 08 09 3 3 color 2 color 3 10 11 0A 0B 4 1 color 3 12 13 0C 0D 4 9 color 3 color 4 14 15 0E 0F 5 7 color 4 16 17 10 11 6 5 color 4 color 5 18 19 12 1...

Страница 17: ...Gobo 2 8 11 8 0B 3 8 Gobo 3 12 15 0C 0F 5 0 Gobo 4 16 19 10 13 7 0 Gobo 5 20 23 14 17 8 4 Gobo 6 24 27 18 1B 10 Gobo 7 28 31 1C 1F 11 Gobo 8 32 35 20 23 13 Gobo 9 36 39 24 27 14 5 Gobo 10 40 43 28 2B 16 2 Gobo 11 44 47 2C 2F 17 Gobo 12 48 51 30 33 19 Gobo 13 52 55 34 37 20 8 Gobo 14 56 59 38 3B 22 4 Gobo 15 60 63 3C 3F 24 3 Gobo 16 64 67 40 43 25 5 Gobo 17 68 71 44 47 27 5 Gobo 18 72 75 48 4B 29 G...

Страница 18: ...o PAN 64 95 40 5F 26 37 PAN TILT inverse size phase see also PAN 96 127 60 7F 38 50 Circle size phase see also PAN 128 159 80 9F 51 62 Circle inverse size phase see also PAN 160 191 A0 BF 63 75 lying eight size phase see also PAN 192 223 C0 DF 76 87 12 Move ment random movement size see also PAN 224 255 E0 FF 88 100 n a 0 63 0 3F 0 25 Special color chaser color color 1 slow fast 64 79 40 4C 26 31 ...

Страница 19: ... 2 Open the 3 screws A B and C at the lamp sheet and remove it 3 Remove the old or broken lamp out of the socket Attention The glass bulb of the lamp can splinter For that reason remove the lamp with safety gloves or some cloth 4 Put in the new lamp securely into the socket Attention Use only the original lamp type 5 Close the M MI IN NI I P PA AT TE EN ND D in reverse order 5 3 Lamp adjustment Th...

Страница 20: ...fixture s light output will be significantly reduced Regular cleaning will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recom mended under no circumstances should alcohol or solvents be used The inside optical system should be maintained only by authorized per...

Страница 21: ...ner airbrush etc Reflector never Lamp never Moveable parts yearly suitable fatty oil Attention 1 Never let optical parts come into contact with oil or grease 2 Wait until all parts are dried up before operating the fixture 6 3 Cleaning the Optical System 1 Pull out the main plug 2 Wait at least 20 minutes after the last operation to cool down the fixture 3 Remove the Roto Head by loosening the 6 h...

Страница 22: ...s anti reflex coated Color 19 dichroic filter plus white Gobos 19 fixed plus open Shutter Strobe Dimmer Strobe effect with variable speed 0 5 5 flashes per second Continuously mechanical dimmer 0 100 Focus Motor driven focus from near to far away Drive Standard DMX 512 3 pole XLR Pin 3 Pin 2 Ground Pin 1 The DMX addressing starts at the DMX address 001 Pan Tilt Max movement 4 turns per second 16 b...

Страница 23: ...6 E Error Code 15 Error Messages 16 F Fuse 9 I Illumination 22 Injury of the retina 6 Invert 12 L Lamp 19 M Maintenance 20 Measures 22 Menu Field 10 Mounting 7 Mounting plate 8 P Pan movement 22 Permanent installation 8 Power supply 9 R Reset 12 Running time 12 S Safety Instructions 6 Secure the M Mi in ni i P PA AT TE EN ND D 8 Software version 1 Special Functions 13 T Technical Specification 22 ...

Страница 24: ...GLP German Light Production V1 11 24 ...

Отзывы: