3
!
Power requirements
The Gerber P2C series of plotters require standard power.
♦
Voltage: 100 to 120 V AC or 220 to 240 V AC
♦
Frequency: 48/62 Hz , single phase
♦
85 VA maximum
!
Work area requirements
The Gerber P2C plotters require ample room to load and unload material. Provide additional
space in the room for storing rolls of material. Material should not be stored on the floor.
P2C Model
Assembled Size
Weight
P2C 600
39.4" long x 13.8" wide x 11.8" high
100 cm x 35 cm x 30 cm
33 lbs.
15 kg
P2C 1200
with stand
62.6" long x 26.9" wide x 41.3" high
159 cm x 68.2 cm x 105 cm
92 lbs.
42 kg
P2C 1600
with stand
89" long x 29" wide x 40" high
226 cm x 74 cm x 101 cm
198 lbs.
90.2 kg
!
!
!
!
Environmental requirements
The room in which the Gerber P2C plotter is installed should be relatively clean
−
the type of
environment in which you could paint
−
without the dust and dirt created by routing or
sandblasting.
Gerber recommends setting up in an air-conditioned environment in order to maintain constant
temperature and humidity. Be sure to allow the equipment and material to reach and remain at
room temperature for 24 hours before cutting. The ambient environment should meet the
following conditions:
Recommended working environment
♦
Temperature: 40ºF to 95ºF/ 5ºC to 35ºC
♦
Humidity: 35% to 80%, non-condensing