REPAIR ANALYSIS PROCEDURE

  

Service Manual

 

2-4

 

 

 

GENERIC RAPS 

Generic RAP 1 

 
This green led is located upper left corner of the main controller pwb and detect the 24 Vdc 
voltage, the led off  generally occurs when interlock circuit open contacts on power supply J8 
pin1 &2 and/or main controller J2 pin 11&12, 24 fuse open on Power Supply PWB .  
Some firmware release can displayed as “Stepper Motor Fault”. when on power on Self Test 
the Folder Controller looses communications with the Drive Controller. 
 

Initial Action 

Power Cycle the Folder and check for the message; close all doors and unsure drive controller 
board red Led is on. 
 

Procedure

 

Check carefully all safety interlock (according to the Mondial Folder version) verifying not 
only the interlock itself but also wiring connections and the correct interlock working point. 

 

Are all safety interlocks correctly working? (to verify shock the switch and see if both contact 
are close all the times and folder firmware level is higher or equal to 3.16). 

Y  

N

  

       Replace and /or adjust safety interlock and check if LED L1 Power Supply PL9.2 is on 

 

Check 24 V fuse F4 on Power Supply. 
Is the Fuse F4 working? 

Y         N

  

Replace the fuse F4 

Check on Drive Controller J1 connector is connected and Red LED 5Vdc is available. 

Y  

N

  

         Check wiring J1 – J14 

 

Check 12 V green led on PWB Main Controller; is it on? 

Y      N 
         

Replace the Main Controller 

 

Check J5 on Main Controller pin 1,2 and J7 on Power supply; is there 12V both? 

Y      N 
        

 Check the wiring between J5 Main Controller and J7 PS1; is it ok? 

         Y      N 

                                

      Replace / restore the wiring 

 

            Replace the Main Controller 

 

Replace the Power Supply.  If the folder does not work open after the Power 
Supply replacement call to Gera Service Team by filling  Problem Report Form  
available at 

http://www.gera.it/wp-

content/uploads/report_form/PROBLEM_REPORT_FORM_ladybird.pdf

 

POWER OFF RAP 

 
Use this RAP when the folder Control Panel LEDs does not light on, or when the UI Selection 

key is pressed 

and  the Cross Folder Exit wheel are not rotating. 

 
Initial Action 

Close all folder door, turn the folder off and on, the folder during the POST runs some motors 

and light on the folder Control Panel led, Press the selection key 

and  the Cross Folder Exit 

wheels should rotate,   if one or more these events are performed  follow the procedure. 
 
 

Procedure 

Remove the folder back panel  REP 2.10 and 

check Led L1 on Power Supply PL 9.3 

Is the green Led on? 

Y      N  

Check if power cable is plug into Iec connector, if main 
switch is on. Are the line fuses F1 and F2 operating?

 

Y      N 

Replace with GERA spare Fuse 1.6A(50Hz) or  Fuse 3.15A (60Hz)

 

                   

   

   Is the Power Supply 24Vdc output available?  If not replace Power Supply PL 9.3 

           Y

 

Check Main Controller 24 Vdc Input J18 and J17  
Is the 3,3Vdc LED on Main Controller Pwb light on? 

    Y      N 
 

Check cabling from PS1 24Vdc output to J18 Main Controller 

  

If there is not an open circuit open a service call to GST 

 

Is the 24Vdc Main Controller LED lit on? 

 

  Y     N 

 

Check cabling from PS1 24Vdc output to J17 Main Controller 

 

If there is not an open circuit up to J17 before change Main Controller open a service 
call to GST 

Check if Stepper Motor Controller PWB PL 9.3 item 4 Led D4 indicating 5Vdc on . 
Is the 5 Vdc LED  on ? 

Y      N 

     Check Main Controller 5 Vdc LED  is on? 

             

       N  

      Troubleshoot connector J16 flat cable  

             

  

 

 Open call to Gera Service Team by filling Problem Report Form  available at 

http://www.gera.it/wp-
content/uploads/report_form/PROBLEM_REPORT_FORM_ladybird.pdf

  

before replace Main Controller PWB. 

Содержание LadyBird I

Страница 1: ...LadyBird I Folder Service Manual D860101X March 2014...

Страница 2: ...RES III SECTION 2 REPAIR ANALYSIS PROCEDURE III SECTION 3 FOLD QUALITY III SECTION 4 REPAIR AND ADJUSTMENT III SECTION 5 PARTS LIST III SECTION 6 GENERAL PROCEDURES III SECTION 7 WIRING DATA III OTHER...

Страница 3: ...iar with the use of any special tools that are required to service this product Service Documentation Revisions This service documentation may be subject to periodic revision in order to reflect any c...

Страница 4: ...eneral Procedures This section contains procedures and Information of a general nature that apply to the machine The General Procedures subsection contains frequently used procedures that relate to th...

Страница 5: ...are commonly found In GERA equipment These symbols are included as an aid to understanding the representations used in the Circuit Diagrams CDs AC and DC Voltage References The expected AC and DC volt...

Страница 6: ...that is closed Switch relay contacts with momentary contacts shown normally open Switch relay contacts with momentary contacts shown normally closed Connectors numbering This symbol indicates the num...

Страница 7: ...entire drawing was the configuration before being changed by the tag number within the circle Signal Nomenclature The signal is named to imply the condition of the machine when the signal is available...

Страница 8: ...rch 2014 Service Manual 1 1 SERVICE CALL PROCEDURE 1 Service Call Procedure 1 SERVICE CALL PROCEDURE 1 1 SERVICE CALL PROCEDURES 1 2 INITIAL ACTION 1 2 FOLDER REGISTRATION 1 3 SYSTEM CHECKOUT 1 3 CSE...

Страница 9: ...lassify the folder problem by using RAP and Fold Quality Section Perform RAP REP ADJ Final Actions FOLD QUALITY PROBLEMS Section 3 Fold Quality FOLD QUALITY SELECTION INDICATION Go to the Generic RAP...

Страница 10: ...e delivered to the output tray Y N Refer to the Initial Action in order to classify the problem and begin your repairs Evaluate the print folding The folding quality is acceptable Y N Go to Section 3...

Страница 11: ...2 2 Sensor default status chart 2 2 STATUS MESSAGE RAPS 2 1 TWO GREEN LED LIT ON TOGETHER 2 1 FAN FOLDER UPPER POCKET SENSOR COVERED RAP ALL 2 1 FAN FOLDER LOWER POCKET SENSOR COVERED RAP ALL 2 2 ala...

Страница 12: ...o locate it count number of beeps ERROR Message RED LED FLASHIG Beeps every 30 sec ENTRY ALARM 1 Beep FAN ALARM 2 Beeps CROSS ALARM 3 Beeps SENSOR DEFAULT STATUS CHART Since the folder has many sensor...

Страница 13: ...Control Panel red Led flashing and emitting 4 beeps The default sensor Led status is light on To locate Upper Pocket Sensor C3 refer to Electric Diagram Procedure The folder sensor C3 led should on i...

Страница 14: ...ROBLEM_REPORT_FORM_ladybird pdf ALARM STATUS RAPS FOLDER ENTRANCE ALARM RAP ALL Use this RAP when the folder stops and the red led is flashing and 1 beep This occurs when the print jams at folder entr...

Страница 15: ...on the Electric Diagram for missed input voltage 12Vdc or sensor signal sent to main Controller PWB Is sensor operating correctly Y N Replace sensors Please check Sensor C2 C3 and relative RAP if pape...

Страница 16: ...er does not work open after the Power Supply replacement call to Gera Service Team by filling Problem Report Form available at http www gera it wp content uploads report_form PROBLEM_REPORT_FORM_ladyb...

Страница 17: ...ce Manual 3 1 FOLDING QUALITY 3 Folding Quality INITIALIZATION PROCEDURE 3 2 FOLD DEFECTS 3 2 FOLD QUALITY DEFINITION 3 2 FOLD QUALITY RAPS 3 3 FQ 1 FOLD SKEW 3 3 FQ 2 FOLD DAMAGE 3 3 FQ 3 FOLD DIMENS...

Страница 18: ...at cause media damage before attempting to fix fold quality problems Some media damage problems can cause fold quality problems To fix folding quality problems 1 Compare the fold defect to the Fold Qu...

Страница 19: ...ly the Cross Folding infeed referring the quick guide Stair and or Skew effect A Wrong Folder and Printer Alignment A Perform Front Rule Adj 1 3 FQ 2 FOLD DAMAGE Defect Probable Cause Corrective actio...

Страница 20: ...fold setup A Cross Trim Adjust panel 2B Print exits unfolded from the fan folder A sensor does not detect the print correctly B NO FOLD program selected A Perform Fold selector position B Check curren...

Страница 21: ...OLDER ADJUSTMENTS 4 5 ADJ 1 1 Mobile Roller Right Side 4 5 ADJ 1 2 Mobile Roller Left Side 4 5 ADJ 1 3 FRONT RULE 4 6 ADJ 1 4 INFEED GROUP PARALLELISM 4 6 3 PROGRAM ADJUSTMENT PROCEDURE 4 7 ADJ 1 1 PR...

Страница 22: ...Overturn down the Assembly carefully until to horizontal position Figure 4 1 Upper Infeed Group Overturn REP 1 2 LEFT COVER REMOVAL 1 Switch off the folder 2 Perform Rep 1 1 In feed Group Overturn 3...

Страница 23: ...t Cover Figure 4 3 Right Cover Reamoval REP 1 4 POWER SUPPLY FRONT COVER REMOVAL Before open the Power Supply Front Cover that s advisable to lift up the mobile blue collector to avoid it obstacles th...

Страница 24: ...Manual 4 4 REPAIR AND ADJUSTMENTS REP 1 5 POWER SUPPLY REAR COVER REMOVAL 1 Switch off the folder and disconnect the Plug 2 Remove the Plate showed below by unscrewing the two fixing screws Figure 4 5...

Страница 25: ...left side Adjustment Figure 4 7 Mobile roller left side Adjust the Mobile Roller distance between the folding rollers Screw clockwise increase the distance Unscrew anticlockwise decrease the distance...

Страница 26: ...ent 1 3 check the parallelism between the infeed group both side and the printer exit Adjustment Perform the parallelism adjustment Acting firstly on left attaching bracket to obtain equal distance fr...

Страница 27: ...both for program P1 210 mm fan and program P2 190 mm fan LONG PLOT Panel mm Address 1A 210 Ad2 2A 210 Ad1 ADJ 1 2 PROGRAM P3 305 and P4 297 CROSS Program P3 305 mm Cross Fold Size Panel Mm Address A1...

Страница 28: ...Ladybird Folder March 2014 SPARE PARTS LIST Service Manual 5 Spare Parts List PL 0 1 SENSORS 5 2 PL 0 2 ELECTRONIC PARTS 5 3 PL 0 3 MOTORS 5 4 PL 0 4 KIT 5 5...

Страница 29: ...d Frontal Sensor 3 7 8 C695419X Barrier Sensor 4 C850405X Datalogic Lateral Sensor ITEM DESCRIPTION 1 Start toothed rollers Sensor 2 No Corss Sensor 3 Start Feeding Sensor 4 Advancing Sensor 5 Start M...

Страница 30: ...nual 5 3 SPARE PARTS LIST PL 0 2 ELECTRONIC PARTS ITEM CODE DESCRIPTION 1 C940403R POWER SUPPLY 230v 2 C340418X RELAY 24VDC 3 C960423R PWB MAIN CONTROLLER REV 3 4 C960403R DRIVE CONTROLLER 5 C940405R...

Страница 31: ...Ladybird Folder March 2014 Service Manual 5 4 SPARE PARTS LIST PL 0 3 MOTORS ITEM CODE DESCRIPTION 1 FEDING MOTOR 2 C860405X FLAP MOTOR 3 CONVEY MOTOR 4 MAIN MOTOR 5 E1 SOLENOIDE 4 M3 5 1 M1 2 MT 3 M2...

Страница 32: ...Ladybird Folder March 2014 Service Manual 5 5 SPARE PARTS LIST PL 0 4 KIT CODE DESCRIPTION CARE PACK...

Страница 33: ...860 SERVICE MANUAL 5 SPARE PARTS...

Страница 34: ...specifications 6 2 CONTROL PANEL 6 3 Folding Programs 6 3 ELECTRONIC PWB 6 4 Main Controller PWB 6 4 Drive Controller PWB 6 4 JC 11 CONNECTOR 6 5 DIAGNOSTIC 6 6 Input Output Test 6 6 MAINTENANCE 6 7 F...

Страница 35: ...ge Requirements 115V 2A 60Hz 230V 1A 50Hz Audible Noise Average Continuous 58dbA max run NEGLIGIBLE Stand by Environmental Relative Humidity 35 to 85 Temperature 60 to 90 Fahrenheit 15 to 32 Celsius P...

Страница 36: ...market the folder is intended for Selection Key PRESS TO SELECT THE FOLD OUTPUT PACKAGE FOR PRINT INTRODUCED MANUALLY Press to perform Manual Eject and clear the folder jams Reset Key Performs RESET F...

Страница 37: ...from Power Supply AMP 2x1 Drive Controller PWB The PWB Drive Controller is located inside the lower panel of the folder It contains the CPU and firmware that controls the stepper motor Main Fan Folde...

Страница 38: ...er into the Folder through the Connector JC11 is for the information necessary between Folder and Printer stop the Printer with Folder Alarm Cut Signal and Starting Folding Process ITEM on JC11 DESCRI...

Страница 39: ...nload the GERA UTILITY 2 5 from GERA web site and install it Download Utility Rel 2 5 Download the zipped file who contains defaults values ini file parameters and firmware Firmware Parameter and Ini...

Страница 40: ...Poor print transportation lack of pressure Rubber rollers Poor print transportation Sensors Poor print sensing resulting in lower fold quality Every 15000 meters folded Maintenance activities Check C...

Страница 41: ...Switch off on the folder If one green LED is lit on the upgrading was successfully done If two LED is lit on do the upgrading procedure again Folder Adjustment Connect the USB serial cable to the P5...

Страница 42: ...made increase the folder safety O Optional If the modification is not necessary and can be installed by CSE choice The serial number of the folders that mount the modification MFG SERIAL N The TAG nam...

Страница 43: ...Ladybird Folder 03 Mar 2014 Service Manual 6 10 GENERAL PROCEDURE...

Страница 44: ...Ladybird Folder March 2014 Service Manual 7 1 WIRING DATA 7 Wiring Data 1 FOLDER WIRING DATA 7 2 BSD 1 1 ELECTRICAL MAIN DIAGRAM 7 2...

Страница 45: ...Ladybird Folder March 2014 Service Manual 7 2 WIRING DATA 1 FOLDER WIRING DATA BSD 1 1 ELECTRICAL MAIN DIAGRAM...

Отзывы: