54
[Alarm Parameters]
Suppress alarm:
After an alarm is triggered, the same alarm will not be reported within
the set time.
Clear alarm:
After an alarm is triggered,
If the same alarm is not triggered within the set time, the alarm will be cleared and
the same alarm can be reported again.
If the same alarm is triggered within the set time, the alarm will not be cleared until
the suppress alarm time expires. Then the same alarm can be reported again.
[Alarm Triggering Mode]
Upload to FTP:
Select to automatically upload snapshots to the specified FTP server
upon motion detection.
Trigger e-mail:
Select to automatically send snapshots to the specified E-mail address
upon motion detection.
Note:
1. For the
Upload to FTP
function, make sure to configure the settings in
3.2.4 FTP
and
3.3.2 Capture
first.
2. For the
Trigger e-mail
function, make sure to configure the settings in
3.2.5 E-mail
and
3.3.2 Capture
first.
[Enable Plan]
Select this option to set the start and end times during which motion detection alarm is
enabled. You can directly drag the mouse to draw a plan or click
Edit
to edit time periods in
the table. You can set up to four periods for each day, and the time periods cannot overlap.
The camera reports alarms during the specified period(s) only.
Figure 3-27