background image

 
 

Note:

 You can identity the Armed Status from the color change in the GV-RK1352 Card 

Reader’s LED, with green / red indicating entering Armed Status and blue standby mode. 
After connecting the control wires of the reader’s LEDs to the outputs on GV-AS Controller,

i. 

Enable the external controls of LED on 

GV-R/RK/DFR Config AP

     

 

ii. Go 

to 

the 

Output Configuration

 page on the Controller’s web interface. Set 

Pulse 

to specify the number of seconds to trigger LED when the output condition, 

ARM 

mode

, is entered. 

         

 

 

Содержание GV-AS210

Страница 1: ...later GV AS410 4110 4111 Firmware V2 11 or later GV AS810 8110 8111 Firmware V2 11 or later GV ASManager V5 0 1 0 or later GV RK1352 Reader Note This document is dedicated to Texecom Intruder Alarm S...

Страница 2: ...the Armed Mode you need to define the output and input functions of a GV AS21 41 81 series Controller and add a Security Card on GV ASManager After the setup is complete present a security card and th...

Страница 3: ...interface click Output Configuration to define the output function Output Type Output Function 1 2 3 2 Set the Output Type to Door associated with this output 3 Select Alarm Keyswitch as the Output f...

Страница 4: ...guration to define the input function 5 Set the Input Type to be the same as the Output Type in Step 2 6 Select Armed status as the input function The controller door will enter the Armed Mode where n...

Страница 5: ...k with the Armed Mode click the Door tab of the Controller Setup dialog box B Click Authentication Schedule and specify the access mode to either Card Mode or Card or Common Mode at different periods...

Страница 6: ...our digit PIN code for the card D Assign the security card to an access group using the Access Group drop down list For details see 4 5 Setting Access Groups in the GV ASManager User s Manual 8 To ena...

Страница 7: ...blue standby mode After connecting the control wires of the reader s LEDs to the outputs on GV AS Controller i Enable the external controls of LED on GV R RK DFR Config AP ii Go to the Output Configu...

Страница 8: ...or any reason the intruder alarm system is not responding correctly you can temporarily disable the Armed Mode Present the security card to the reader followed by entering the PIN code five times cons...

Отзывы: