18
Fire Action
Locks or unlocks the door when a fire condition occurs. Otherwise,
remains the door’s current state by selecting
Unchanged
.
Alarm Continuous
Time
Sets the time (1 to 10 sec.) that the alarm will continuously go off
before it ends.
Relay On Time
Sets the time (1 to 600 sec.) that a gate remains open after which
the gate will automatically be closed.
[Alarm]
Select
Yes
or
No
to enable or disable the alarm function. The options available vary
depending on
Door Control
,
Parking Control
and
Elevator Control
selected in the
Function Configuration
page (
Figure 3-6
):
If you have defined the alarm conditions in the
Input Configuration
(
Figure 3-9
)
and
Output
Configuration
(
Figure 3-10
)
pages, remember to activate the corresponding alarms here;
otherwise, even though the alarm conditions are met, the expected alarm will not be
triggered. The default settings for all the alarms are set to
NO
.
Option
Description
Held Open
This alarm activates whenever the door is held open over the
specified time period.
Forced Open
This alarm activates whenever the door is opened by force.
Fire Alarm
This alarm activates whenever fire is detected.
Access Denied
This alarm activates whenever entry is denied due to invalid card or
password presented.
Tamper
This alarm activates whenever the sensor for tampering alarm is
triggered. The tampering alarm sensor needs to be installed
separately and the triggering conditions depend on the type of
sensor installed, e.g. opening of the controller’s cabinet.
[Common Password]
When
Fixed Card/Common Mode
is selected as
Authentication Mode
in
the
Function
Configuration
(
Figure 3-6
)
page, you can gain access by using a card or entering this
Common Password (door’s password).