16
[Series Function (APB & Fire)]
You can set Anti-Passback and fire sensor functions across multiple controllers. The Anti-
Passback means that a card used on an entry door/gate cannot access the same entry
door/gate again unless it has been used on a corresponding exit door/gate. For details on
setup, see
Chapter 6 Anti-Passback
on
GV-ASManager
For the fire sensor function, when the fire sensor of the associated controller is triggered, the
fire sensor on GV-AS1620 will also be activated.
Enable/Disable:
Enables or disables Anti-Passback and fire sensor functions.
Info IP:
Enter the IP address of the next corresponding controller.
[Wiegand Card Filter Setting]
Wiegand A/B Filter:
Enable to avoid recording repeated access logs, from the same
card via Wiegand port A or B, within the duration set.
Wiegand A/B Filter Duration:
Set the duration of filter, from 3 ~ 60 seconds.
[Camera Mapping]
You can assign a camera to capture snapshots upon card presented. The captured
snapshots will be saved to the built-in flash drive of GV-AS1620 and then transferred to the
Access Log on GV-ASManager whenever GV-ASManager resumes connection after it has
been disconnected.
Enable/Disable:
Enables or disables the camera mapping function.
First Camera:
Type the IP address of the assigned camera to take snapshots.
Type the
User Name
and
Password
of the camera to complete the mapping process.
[HTTP Event (Card Log Notification)]
Select
Enable
to send access and event logs of the controller to the configured
event IP
address and
Port
number.
Note:
This function is supported only on GV IP cameras except GV-EBD / ABL / ADR / AVD /
TDR / TBL / TVD series, GV-VD8700 and FD8700-FR.