[Door/Gate A] 

Select the function type and authentication mode for the use of Door/Gate A. 

„

 

Function: 

Select the function for GV-AS100 on Door/Gate A. 



 

Door Entry Control:

 Sets GV-AS100 as entry reader on the Door A. The Weigand 

reader connected on GV-AS100 will be set as exit reader.  



 

Door Exit Control: 

Sets GV-AS100 as exit reader on the Door A. The Weigand 

reader connected on GV-AS100 will be set as entry reader. 

 



 

Parking Entry Control: 

Sets GV-AS100 as entry reader on the parking Gate A.

 



 

Parking Exit Control: 

Sets GV-AS100 as exit reader on the parking Gate A. 

 



 

Elevator Control: 

GV-AS100 reader is installed in the elevator for access control. 

 

 

 

„

 

Authentication Mode: 

Select the authentication mode for the Door/Gate A. 



 

Local Unlock Mode: 

Remains open. The held-open state cannot be cleared 

through GV-ASManager. 

 



 

Local Lock Mode: 

Remains locked. The locked state cannot be cleared through 

GV-ASManager. 



 

Fixed Card Mode: 

Remains in the card mode and ignores the authentication 

schedule of GV-ASManager.

  



 

Fixed Card + PIN Mode: 

Remains in the Card and PIN Code mode and ignores the 

authentication schedule of GV-ASManager.

  



 

Fixed Card/Common mode: 

Remains in the Card or Common mode and ignores 

the authentication schedule of GV-ASManager. 



 

Authentication Schedule Mode: 

Follows the authentication schedule set on GV-

ASManager. 

[Door/Gate B] 

This option becomes available only after 

Door/Gate B

 is selected from the 

ASBox Wiegand

 

option above. 

Select the function type and authentication mode for the use of Door/Gate B. The Function 
and Authentication Mode options are the same as those of Door/Gate A. But remember that 
the settings here are used to define the Wiegand reader connected to GV-ASBox. 

Note: 

The 

Parking Entry Control 

and 

Parking Exit Control

 only work when the sensor 

input of Car Detection is activated. When the card is present but the sensor input is not 
activated, the message “No Car In Zone” will appear in the GV-AS100 LCD. 

Содержание GV-AS100

Страница 1: ...GV AS Controller Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use Hardware Installation Guide...

Страница 2: ...is manual is accurate GeoVision is not responsible for printing or clerical errors GeoVision Inc 9F No 246 Sec 1 Neihu Rd Neihu District Taipei Taiwan Tel 886 2 8797 8377 Fax 886 2 8797 8335 http www...

Страница 3: ...2 4 C Switches 8 1 2 5 Connecting the Power 9 1 2 6 Fitting the Battery 9 1 3 Programming Mode 10 1 3 1 Quick Reference of Programming Table 12 1 3 2 Accessing the Card Manager 13 1 3 2 A Adding a Ca...

Страница 4: ...Features 50 2 1 2 Packing List 50 2 1 3 Models 50 2 1 4 GV AS200 Board Layout 51 2 2 Installation 52 2 2 1 Connecting the PC 52 2 2 2 Connecting Inputs 53 2 2 2 A Button Inputs 53 2 2 2 B Senor Input...

Страница 5: ...AS200 Specifications 79 2 7 Troubleshooting 80 3 GV AS400 Controller 81 3 1 Introduction 82 3 1 1 Main Features 82 3 1 2 Packing List 82 3 2 Installation 84 3 2 1 Connecting Card Readers 84 3 2 1 A W...

Страница 6: ...F Output Function 111 3 4 4 Extended Device 112 3 4 4 A Extended Reader 112 3 4 4 B Extended I O 113 3 5 Optional GV ASKeypad 114 3 5 1 Installation 114 3 5 2 Operation 115 3 5 2 A Setting Parameters...

Страница 7: ...his user manual includes three types of GV AS Controllers GV AS100 One door controller and standalone system See page 1 GV AS200 Two to four door controller See page 49 GV AS400 Four door controller S...

Страница 8: ...that can be connected to any standard access control panel GeoFinger Reader The reader supports two operation modes Fingerprint Only and Fingerprint Card In Fingerprint Only mode the fingerprints are...

Страница 9: ...ard readers for entry and exit For example a building includes both office and laboratory applications One way traffic Two doors are applied for entry and exit separately For example in a parking lot...

Страница 10: ......

Страница 11: ...1 GV AS100 Controller...

Страница 12: ...used as a standalone unit the programming is either done on the keypad or from the software GV ASManager through the RS 485 connection GV AS100 is suitable not only for any normal door control but als...

Страница 13: ...dalone networked mode Easy programming from keypad Anti Passback APB support Built in 3 digital inputs and 2 relay outputs 1 Weigand output 26 64 bits for extra reader programming 1 1 2 Packing List G...

Страница 14: ...13 IN3 Fire 12 IN2 Button 11 IN1 Sensor GND 10 PWR Out 9 12V Data1 8 Data0 7 RS485 6 B RS485 5 B RS485 4 A RS485 3 A GND 2 PWR In 1 12V Figure 1 3 Pin Function Pin Function Pin Function Pin Function 1...

Страница 15: ...eader for wiring Pin Function 7 Wiegand Data 0 8 Wiegand Data 1 9 12V Power Supply 10 GND 1 2 2 Connecting Input Devices GV AS100 supports 3 types of inputs 1 Sensor inputs e g door status sensor 2 Bu...

Страница 16: ...C Continuous Load Current 5A NO 3A NC Note Absolute Maximum Ratings are those values beyond which damage to GV AS100 circuit board may occur Continuous operation of GV AS100 at the absolute rating lev...

Страница 17: ...PORTANT To enable connecting to PC Switch 1 must be turned on See 1 2 4 C Switches 1 2 4 A RS 485 Connection The figure below illustrates the RS 485 connection to the computer For this connection the...

Страница 18: ...n Pin Function Pin Function 1 Power In 12V 3 RS 485 A 5 RS 485 B 2 GND 4 RS 485 A 6 RS 485 B Also see 1 4 3 A Connecting GV AS100 1 2 4 C Switches Switch 1 When Switch 1 is ON GV AS100 can connect to...

Страница 19: ...d only be applied to the unit when all connections are completed and tested 1 2 6 Fitting the Battery GV AS100 includes a 3V lithium battery providing power to database and real time clock circuitry W...

Страница 20: ...ss any four digits on the keypad to change the default value The double confirmation of the new PIN code is required After this the LCD should display the message of success After the Master Card is c...

Страница 21: ...amming GV AS100 you also need to know the following keys Key Function Used to cancel the selection or go back to the previous page Used to save the data that was modified or programmed in the system a...

Страница 22: ...de Fixed Card PIN Fixed Card Common Local Unlock Mode Local Lock Mode AS100 Function GV ASBox Control Type Door Entry Type Anti Passback Door Exit Type Anti Passback Parking Entry Type Anti Passback P...

Страница 23: ...displays Add New Card 3 Press The LCD displays Enter New Card 4 To add a card you can either press the card number or present the card to the unit The LCD displays the card number and these options 1...

Страница 24: ...granted access and no one can program the unit Only the security card that is associated with a PIN code can be used to disarm the unit 1 3 3 A Enabling the Security Mode Before you can access the se...

Страница 25: ...the time time zone and enables daylight saving Set AS100 ID Sets the ID of GV A100 from 1 to 255 Set Auth Mode Sets an authentication mode for the door gate Auth Schedule Follows the authentication s...

Страница 26: ...nction Master PIN Change Changes the PIN code of the Master Card Local Rest Time Sets the time 1 to 255 sec that a door gate remains open after which the door will automatically be locked Set Held Ope...

Страница 27: ...o GV ASBox failed Comm Normal The connection to GV ASBox succeeded Memory s State Displays the memory usage of GV AS100 Capacity Displays the total number of events that can be recorded on GV AS100 Th...

Страница 28: ...t to factory defaults IMPORTANT Restoring default settings will delete all cards enrolled on GV AS100 1 Press the code 737 RES 2 Present the Master Card and enter PIN Code The LCD displays Default Set...

Страница 29: ...Main Features Add TCP IP networking capability to GV AS100 Extend GV AS100 from 1 door to 2 door controller Support 1 Wiegand reader of 26 to 64 bits Support 8 digital inputs and 8 relay outputs 4 sp...

Страница 30: ...M4 NO4 NC3 COM3 NO3 NC2 COM2 NO2 NC1 COM1 NO1 Com A Com A DI4 DI3 DI2 DI1 Com B Com B DI8 DI7 DI6 DI5 Battery ON OFF Web Setting GND 12V Ethernet 12V D0 D1 GND A A B B Weigand GV AS100 GV AS100 RS 485...

Страница 31: ...n assignments of related connectors on GV ASBox for connection to GV AS100 Figure 1 10 Pin Function Pin Function Pin Function 12V 12V Power Supply to GV AS100 A GV AS100 Connection B GV AS100 Connecti...

Страница 32: ...or wiring Pin Function GND GND for the Power Supply D0 Wiegand Data 0 D1 Wiegand Data 1 12V 12V Power Supply To define the reader you need to use the GV AS100 Web interface See 1 4 5 B b Parameter Set...

Страница 33: ...inputs DI1 to DI8 All inputs are dry contact and can be configured as normally open NO or normally closed NC through the Web interface The default value is NO The figure below shows the pin assignmen...

Страница 34: ...See To combine door access with relay activation below Figure 1 13 Outputs 1 4 Absolute Maximum Ratings Breakdown Voltage 277V AC 30V DC Continuous Load Current 5A NO 3A NC Note Absolute Maximum Ratin...

Страница 35: ...ether and connect the point on the external power supply to the NO or NC of GV ASBox based on the state of the output device NO5 COM5 NC5 NO6 COM6 NC6 Output Device External Power Supply Figure 1 14 T...

Страница 36: ...gh the Web interface When the switch is set to OFF Advanced Settings are not accessible For details on Advanced Settings see 1 4 5 B Advanced Settings 1 4 3 F b Resetting the GV ASBox To reset GV ASBo...

Страница 37: ...in are admin Note the computer used to set the IP address must be at the same network or subnet sequence assigned to GV ASBox 3 GV ASBox is able to support two network environments Fixed IP and DHCP S...

Страница 38: ...V AS100 set the device time and edit the input output functions The changes in some of the Advanced Setting page will effect the options available on other pages Below is a diagram drawing the relatio...

Страница 39: ...anager to differentiate among multiple units of GV AS100 ID number can only be between 1 and 255 ASBox Wiegand Select the function for Wiegand Input on GV ASBox from the drop down list No Function Wie...

Страница 40: ...t be cleared through GV ASManager Fixed Card Mode Remains in the card mode and ignores the authentication schedule of GV ASManager Fixed Card PIN Mode Remains in the Card and PIN Code mode and ignores...

Страница 41: ...rolled area For details on setup see Chapter 6 Anti Passback on GV ASManger User s Manual Enable Disable Enables or disables the Anti Passback function Info IP Enter the IP address of the next corresp...

Страница 42: ...Parameter Setting change based on your settings for Door Gate A and Door Gate B in the Function Setting page Figure 1 17 Figure 1 18 IMPORTANT Once connecting to GV AS100 GV ASManager will load its pa...

Страница 43: ...oor remains open after which the door will automatically be locked The option is only available when Door Entry Exit Control is selected Held Open Time Sets the time 5 to 9999 sec that a door gate can...

Страница 44: ...Figure 1 17 these options become available Option Description Held Open This alarm activates whenever the door is held open over the set period of time Forced Open This alarm activates whenever the do...

Страница 45: ...Function Setting page Figure 1 17 you can either gain access through the use of a card or use this Common Password to enter Figure 1 21 AS100 Input Name Rename the input names for the four AS100 inpu...

Страница 46: ...e in the Function Setting page Figure 1 17 The listed number of outputs will change depending on the chosen Output Type in the In Out Function page Figure 1 25 Indicates the current input output devic...

Страница 47: ...Shows the number of cards currently stored in GV AS100 Card List Displays the list of cards stored in GV AS100 If there are many pages you can choose to jump to any page by entering the page number i...

Страница 48: ...0 Local Time Disable Disable the manual configuration of time and date Setup Enable the manual configuration of Time Zone Date and Time for GV AS100 Daylight Savings Time DST Disable Disable the manua...

Страница 49: ...d select the most fitting Input Type No 3 Figure 1 26 and Input Function No 4 Figure 1 26 to describe the sensor input Through the sensor input an alarm event can be detected and it can then trigger t...

Страница 50: ...when triggered Door A or B Fire Zone Tamper Zone Exit Button Door Contact Depending on the type of sensor and the location where it is installed select the best Input Function name to fit the sensor...

Страница 51: ...ger the Tamper alarm Output Function Here you can define each output device that is connected to GV ASBox such as locking devices various alarms or Exit Button Only Output 5 to Output 8 can be connect...

Страница 52: ...Figure 1 17 3 Output Function Configure the output function Options available for the output function change based on your setting of Output Type above When Door Entry Exit Control is selected in the...

Страница 53: ...Output is triggered when the security card is presented Entry Card Output is triggered when the card is presented to enter the parking gate Gate Exit Card Output is triggered when the card is present...

Страница 54: ...ther through AND OR AND means that all conditions with AND must be triggered before the output is triggered OR means that only 1 of the condition with OR is needed to be triggered before the output is...

Страница 55: ...Button Exit Button Normal Toggle Pulse Normal Lighting Toggle Lighting Pulse Lighting Door Contact Car Detection Select None to disable the condition or select between Input 1 and Input 8 to trigger t...

Страница 56: ...ears Figure 1 30 Define each GeoFinger reader connected to GV AS100 Select which door that the GeoFinger is installed and type XID number serial number found on GeoFinger Click Submit to detect GeoFin...

Страница 57: ...ata Power 100 240V AC 50 60Hz 1 Wiegand interface 26 64 bit format Wiegand Interface 12V DC Power Supply 200mA Communication Protocol RS 485 Input 3 inputs dry contact NO NC Digital I O Output 2 outpu...

Страница 58: ...6 64 bit format Wiegand Interface 12V DC Power Supply 200mA Communication Protocol RS 485 Input 3 inputs dry contact NO NC Digital I O Output 2 outputs Operating Temperature 0 65 C 32 149 F Operating...

Страница 59: ...2 GV AS200 Controller...

Страница 60: ...connection or optional Ethernet Module for programming Optional hot swappable LCD keypad for a quick programming 2 1 2 Packing List GV AS200 Power Adaptor DC 12V 2 1 3 Models GV AS200 has the followi...

Страница 61: ...e ECE 1 12V Voltage Input ECE 1 Dry Contact Input Door Relay type NC ON Green ON Door Open Flash Hold Open Alarm Yellow ON Open Door Button Active Red ON Fire Alarm Flash Force Alarm Green ON Door Ope...

Страница 62: ...access information and alarm messages from GV AS200 The communication link between the computer and GV AS200 can be either RS 485 or network The default value is set to RS 485 with 57600bps For networ...

Страница 63: ...ton 1 Sensor 2 Sensor 2 Input Contact Switch Input Contact Switch Figure 2 3 The inputs located at the top right of the GV AS200 module are illustrated as shown below Figure 2 4 The factory defaults o...

Страница 64: ...the Sensor inputs set your Sensor device to dry or wet contact Refer to Input Contact Switches below 2 2 2 C Fire Inputs The Fire inputs can connect to a fire detection device such as smoke detector T...

Страница 65: ...amper Fire Button Sensor Door A B C D ON NC type OFF NO type Input type ECE 1 2 3 4 5 6 7 8 ON Figure 2 6 2 2 3 Connecting Outputs GV AS200 supports three types of relay outputs for each door 1 Door o...

Страница 66: ...door relay is set to be normally open Door Relay of Normally Open FIRE FIRE FIRE Figure 2 9 2 2 3 A Door Outputs The Door outputs can operate a door locking device such as electromechanical strikes an...

Страница 67: ...locking and alarm devices must use the same voltage otherwise device damage may occur 3 If the door locking device Door outputs is a grounded circuit type NC the emergency door release device Urgent o...

Страница 68: ...AS200 12V D0 D1 GL RL BZ GND Wiegand D 12V Wiegand Card Reader Card Reader AND RS 485 GND Wiegand Figure 2 12 2 2 4 A Wiegand Readers GV AS200 provides up to 4 Wiegand inputs Wiegand A B C D for conn...

Страница 69: ...n GV AS200 By default GV AS200 is set to the Wiegand signal For the RS 485 communication you need to change the parameter GV Reader ID to Extended Wiegand by using GV ASKeypad See 2 4 2 A Setting Para...

Страница 70: ...d control Wiegand C Button inputs Non Non One way traffic Wiegand C Non Non Wiegand D RS 485 Card Readers The default 2 door applications Door A and Door B Door A Door B Work Mode In Out In Out One wa...

Страница 71: ...r B Power Connectors Power The black line of the power cable represents negative the red line of the power cable represents positive Output Input Output Door B Door A Power DC 12V DC 12V Power Power P...

Страница 72: ...ore the GV AS200 module 1 Plug the GV ASKeypad to GV AS200 This step is mandatory 2 Remove the jumper cap from the Default jumper 3 Press the Reset button 4 Replace the jumper cap back to the Default...

Страница 73: ...ontroller 63 2 2 3 3 Status LEDs Door A Door B Door C Door D LED Light On Flashing Green LED Door open Alarm Door held open Yellow LED Door opener active Password Fire detector active Alarm Tamper sen...

Страница 74: ...V AS200s installed at different locations 2 4 1 Installation 1 Open the GV AS200 cabinet 2 Flip both clips of the 26 pin connector on the GV AS200 module 3 Use the supplied 26 pin ribbon cable to conn...

Страница 75: ...settings Press to return to the home page Option Function Set Local Time Sets the time and specify the time zone of GV AS200 Set AS200 ID Sets the ID of GV AS200 Set Work Mode Sets one authentication...

Страница 76: ...e user to present his card to be granted access Release Mode The mode keeps the door in an unlock status with the reader Card Password The mode requires the user presents his card and then enters the...

Страница 77: ...e GV AS200E over the network 2 5 1 Installing GV AS200E on a Network GV AS200E is able to support two network environments Fixed IP and DHCP Depending on your network choose Fixed IP for a static IP a...

Страница 78: ...browser and type the default IP address https 192 168 0 100 This dialog box appears Figure 2 16 2 Click default value admin for both User name and Password and click OK This page appears Figure 2 17 3...

Страница 79: ...If your network environment is using the dynamic IP address from a DHCP server please use one of the following DDNS servers to map a dynamic IP address to a static domain name or device name For LAN...

Страница 80: ...r GV ASManager or a separate computer The wiring of the LocalDDNS application is illustrated as below Figure 2 18 Installing LocalDDNS Server To install the LocalDDNS Server in a computer insert the S...

Страница 81: ...n dialog box Figure2 16 appears 2 In the User Name and Password fields type default value admin and 1234 respectively Click OK The Network Configuration page Figure 2 19 appears 3 Click Enable and sel...

Страница 82: ...AS200E can be accessed with the device name Note 1 The default value of Device Name is user If more than one GV AS Controller is connected to the GV ASManager assign each controller a different devic...

Страница 83: ...e from the website of the DDNS service provider There are 2 providers listed in GV AS200E GeoVision DDNS Server and DynDNS org To register at the GeoVision DDNS Server see the following instructions F...

Страница 84: ...in in the Re type Password field for confirmation 4 In the Word Verification section type the characters or numbers shown in the box For example type i8UCY in the required field Word Verification is n...

Страница 85: ...The login dialog box Figure2 16 appears 2 In the User Name and Password fields type default value admin and 1234 respectively Click OK The Network Configuration page Figure 2 24 appears 3 Click Enable...

Страница 86: ...hree different keys for data encryption The default 3DES Code1 is 12345678 Device Port Keeps the default value 4000 Or modify it to match that of GV ASManager Mac Address Indicates the MAC address of...

Страница 87: ...utton to open the firmware file bin 3 Click the Upload button This update procedure may take 60 seconds to complete 4 When the Update is complete a dialog box appears and asks you to reboot the system...

Страница 88: ...ation page modify the login name and password The password is case sensitive and is limited to 4 characters with the choices of a z and 0 9 Figure 2 28 2 5 2 D Setting Controller ID and Work Mode The...

Страница 89: ...Number of Doors 2 doors Sensor Port Per Door Exit Button Door Sensor Fire Sensor Reader Tampered Output Device Per Door Electric Lock Alarm Device Emergency Device LED Indicator Per Door 3 LEDs indic...

Страница 90: ...d reader is ON 2 If the card reader is connected over a long distance use two additional resistors of 10K ohms to solve the problem Insert one resistor between D0 and 12V and insert the other resistor...

Страница 91: ...3 GV AS400 Controller...

Страница 92: ...d GeoFinger readers through RS 485 connection Built in 16 digital inputs and 16 relay outputs I O capability expandable to 64 digital inputs and 64 relay outputs with GV IO USB Box connected Suitable...

Страница 93: ...0 Board Layout 1 2 3 4 5 6 7 8 ON EGE 1 2 3 4 5 6 7 8 ON EGE RS 485 NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM Wiegand A Wiegand B Wiegand C Wiegand D Wiegand E Wi...

Страница 94: ...necting Card Readers GV AS400 supports two types of card reader interfaces Wiegand and RS 485 The Wiegand interface is compatible with any Wiegand card readers of 26 to 64 bits The RS 485 interface is...

Страница 95: ...ssignments of Wiegand inputs on GV AS400 Please consult the documentation of your Wiegand reader for wiring Pin Function GND GND of the Power Supply D0 Wiegand Data 0 D1 Wiegand Data 1 12V 12V Power S...

Страница 96: ...12V GND D0 D1 12V GND D0 D1 12V GND D0 D1 12V GND D0 D1 12V GND D0 D1 12V GND D0 D1 12V Figure 3 3 Electric Wires on GV Reader RS 485 on GV AS400 Red 12V Blue RS 485 Light Blue RS 485 Black GND On GV...

Страница 97: ...tor that turns ON to provide a visual indication that the input device is activated Figure 3 4 Use the switch as shown below to change the input state for NO or NC When the switch is pushed up the sta...

Страница 98: ...cation that the output device is activated Besides having the on board capability of monitoring 16 outputs GV AS400 can be expanded to 64 outputs if 4 units of GV IO Boxes 16 Ports are connected For d...

Страница 99: ...cept the power from GV AS400 circuit board Check if your output device meets the following absolute maximum ratings before connecting it to any of outputs 9 16 Breakdown Voltage 350V DC 24V AC Continu...

Страница 100: ...s 9 16 The following figure and table shows how to connect the beeper wire of GV Reader to GV AS400 GND RS485 RS485 12V GND D0 D1 12V OUT09 Figure 3 7 Electric Wires on GV Reader Output on GV AS400 Ye...

Страница 101: ...e GV AS400 stores this information on the database for later transmission 3 2 5 Connecting the Power The supplied AC adaptor can be connected to any power source supplying from 100 to 250V Using the s...

Страница 102: ...16 ports of inputs and outputs respectively Connect GV IO Box to the RS 485 connectors as illustrated below Multiple GV IO Boxes of different port types can be connected on a single RS 485 cable to w...

Страница 103: ...oviding power to database and real time clock circuitry When the power in the battery becomes low the message Low Battery will appear on GV ASKeypad In this case please replace the battery The databas...

Страница 104: ...is set to the right position Advanced Settings are not accessible For details on Advanced Settings see 3 4 Web Based Configurations Figure 3 12 3 3 2 Resetting the GV AS400 1 To reset GV AS400 press...

Страница 105: ...ay take up to 3 minutes to restore Basic Settings of GV AS400 to default factory values Figure3 14 To restore All Settings to factory defaults 1 Remove the jumper cap from JP6 to JP7 2 Press the Reset...

Страница 106: ...AS400 is https 192 168 0 100 The default Username and Password for login are admin Note the computer used to set the IP address must be at the same network or subnet sequence assigned to GV AS400 3 G...

Страница 107: ...device time and edit the input output functions The changes in some of the Advanced Settings page will effect the options available on other pages Below is a diagram drawing the relationships between...

Страница 108: ...AS400 ID number can only be between 1 and 255 Door Gate Select the function type and authentication mode for the use of Door Gate A B C and D Function Select the function for the reader connected to...

Страница 109: ...ode Follows the authentication schedule set on GV ASManager Anti Passback This option lets you set the Anti Passback function across multiple door controllers The Anti Passback means that a card used...

Страница 110: ...contents of Parameter Setting change based on your settings for Door Gate in the Function Setting page Figure 3 17 Figure 3 18 IMPORTANT Once connecting to GV AS400 GV ASManager will load its paramet...

Страница 111: ...n Locks or unlocks the door when a fire condition occurs Otherwise remains the door s current state by selecting Unchanged Alarm Continuous Time Sets the time 1 to 10 sec that the alarm will continuou...

Страница 112: ...set period of time Forced Open This alarm activates whenever the door is opened by force Fire Alarm This alarm activates whenever fire is detected Access Denied This alarm activates whenever entry is...

Страница 113: ...cted as Authentication Mode in the Function Setting page Figure 3 17 you can either gain access through the use of a card or use this Common Password to enter Figure 3 19 Click Submit button to save t...

Страница 114: ...0 Local Time Disable Disable the manual configuration of time and date Setup Enable the manual configuration of Time Zone Date and Time for GV AS400 Daylight Savings Time DST Disable Disable the manua...

Страница 115: ...ribe the sensor input Through the sensor input an alarm event can be detected and the event may also trigger the alarm Figure 3 22 1 Input Type Configure the input type Input Type defines the type of...

Страница 116: ...e Door Contact sensor detects unauthorized access a Force Open type of event occurs and the event may trigger the Force Open alarm Gate Fire Zone Tamper Zone Exit Button Car Detection See the Door Inp...

Страница 117: ...cking devices and Exit Button Select from the drop down list to configure the Output Type No 1 Figure 3 24 Depending on the chosen Output Type either Output Function No 2 Figure 3 24 or Output Conditi...

Страница 118: ...Output Type Output Function Description Electric Lock Output is triggered when the card is presented to open the locking device Event Alarm Output is triggered when the defined alarm events occur Secu...

Страница 119: ...01 08 Gate Gate Open Alarm Output is triggered when the parking gate is open Beeper Green LED Output 09 16 Gate Red LED See the same function above When Relay is selected as Output Type these Output...

Страница 120: ...tions as AND and certain conditions as OR For Pulse output type the output is triggered for the amount of time set in the Sec field seconds In the Output Condition settings these Output Type and Outpu...

Страница 121: ...nges to its previous state 3 4 3 F Output Function In the left menu click Wiegand Setting This AS400 Wiegand Configuration page appears Use the drop down list to select the location where the Wiegand...

Страница 122: ...ine each GV Reader connected to GV AS400 Select the ID number of the GV Reader and use the drop down list to select the function that the GV Reader is used for GeoFinger Function Define each GeoFinger...

Страница 123: ...ck Extended I O This AS400 Extended I O Configuration page appears The page defines the inputs and outputs on the GV I O Box which is connected to GV AS400 The options in this page are the same as tho...

Страница 124: ...ASKeypad around to access GV AS400 installed at different locations 3 5 1 Installation 1 Flip both clips of the 26 pin connector on GV AS400 2 Using the supplied 26 pin ribbon cable connect GV ASKeyp...

Страница 125: ...ting to GV AS400 GV ASManager will load its parameters to GV AS400 That means some of configurations you have configured may be overwritten by GV ASManager later 1 Press the code 738 2 Press the defau...

Страница 126: ...s the door gate to be exit or entry For the same function see3 4 Web Based Configurations 3 5 2 B Displaying System Information To display system information press the code 347 To change options or vi...

Страница 127: ...only supplies 12V power combining with GV AS Power Board GV AS 400 can directly drive output devices of 24V AC DC and 10V to 13V DC Additionally GV AS Power Board supports the battery backup to ensure...

Страница 128: ...ource is AC but the Vout Swtich is switched to DC Output the two power outputs of 24V DC will be enlarged to 30V DC 10V to 13V DC GV AS Power Board provides six power outputs of 10V to 13V DC in order...

Страница 129: ...device Figure 3 32 3 6 3 Connecting the Power GV AS Power Board accepts the power input of either 24V AC or 24V DC After wiring the power source to the proper connectors on GV AS Power Board turn the...

Страница 130: ...the battery is connected the Power and Charging LEDs will light When the mains supply is removed and the battery voltage level is above 10 2V the Discharging LED will light and the battery will suppo...

Страница 131: ...Readers max 4 GV Readers 26 64 bit format Wiegand Interface 12V DC power supply 200mA Communication TCP IP Input 16 inputs dry contact NO NC Output 8 relay outputs 8 photo relay outputs Operating Tem...