Problem:
The skimmer is set too high.
Solution:
Recheck the water and product levels and reset the skimmer assembly (use the
installation procedures described in
Section 2: System Installation and Operation
).
Problem:
The canister vent is blocked.
Solution:
Make sure that the holes in the suspension fitting are clear of debris. The PRC will not
operate if these holes are plugged.
Problem:
The intake assembly is obstructed or the coiled product hose is kinked.
Solution:
Refer to
Section 3: System Maintenance
.