Geotech 28738 Скачать руководство пользователя страница 9

GEOTECH PVT REMOTE GATEWAY Manual

2015-11-30

5

Product Information

Item No.

Item

Illustration

Description

COMPATIBLE EQUIPMENT

Refer to separate manuals!

Direct push piezometers

10591

Piezometer with memory.
25 m wire.

Logging direct push pie-
zometer

with

memory.

Range 400kPa.

10590

Piezometer without memory.
25 m wire.

Direct push piezometer
without memory. Range
400kPa.

27928

Piezometer with memory
2MPa.

Logging direct push pie-
zometer

with

memory.

Range 2MPa. Note: Cable
length

and

type

to

be

specified separately.

29029

Piezometer without memory
2MPa.

Direct

push

piezometer

without

memory.

Range

2MPa. Note: Cable length
and type to be specified
separately.

19653

Piezometer cable

Standard cable for piezom-
eter. Permanently mounted
on piezometer from factory.
Specify length upon order-
ing.

10663

Special cable PVT

Double insulated copper
cable. Permanently mount-
ed on piezometer from
factory. Specify length up-
on ordering.

On
request

Direct push piezometer with
special characteristics avail-
able on request.

Direct push piezometer
with special characteristics
available on request.

Piezometer for membrane

filter tip or open standpipe

20500

Electronic transducer

Portable electronic pres-
sure transducer with needle
for filter tip 12912, 24560
and similar.

Can also be used without
the needle for water level
measurements in open
standpipe.

12912

Filter tip, Stainless steel.

Filter tip – closed type with
membrane. Stainless steel.
Connection pipe included.

24560

Filter tip, plastic

Filter tip – closed type with
membrane. Plastic. Con-
nection pipe included.

The GEOTECH PVT product family is being continuously developed and improved. We therefore reserve
the right to changes of the information above.

Содержание 28738

Страница 1: ...nual 2015 11 30 USERS MANUAL GEOTECH PVT REMOTE GATEWAY Ingenj rsfirman Geotech AB Datav gen 53 SE 436 32 ASKIM G teborg Sweden Ph 46 31 28 99 20 Fax 46 31 68 16 39 E mail info geotech se www geotech...

Страница 2: ...GEOTECH PVT REMOTE GATEWAY Manual 2015 11 30...

Страница 3: ...ion 8 2 6 3 Installation 8 Required equipment 8 3 1 Preparations 8 3 2 Installation 10 3 3 4 Maintenance 10 Charging of batteries 10 4 1 Authorized Workshops 11 4 2 Trouble Shooting 11 4 3 Appendix 1...

Страница 4: ......

Страница 5: ...is of information that was available at the time that the publication was written The information can change at any time Ingenj rsfirman Geotech AB reserves the right to change or update the content o...

Страница 6: ...me between visits The built in battery can easily be exchanged upon visit or charged on site from via the separate USB charger The unit can optionally be equipped with a photovoltaic solar panel The g...

Страница 7: ...llu lar phone network Sub scription and SIM card to be provided locally by the customer mini SIM 25 x 15 mm Dimensions 180 x 255 x 110 mm Weight 2 2 kg included in 28738 PVT Gateway setup soft ware So...

Страница 8: ...prior notice 28776 PVT Gateway solar panel Photovoltaic solar panel for charging Gateway batter ies Design may change without prior notice Spare parts 28746 PVT Gateway battery Rechargeable battery fo...

Страница 9: ...rom factory Specify length upon order ing 10663 Special cable PVT Double insulated copper cable Permanently mount ed on piezometer from factory Specify length up on ordering On request Direct push pie...

Страница 10: ...e reduced if used in very cold environment If you need longer time between visits or more fre quent loggings updates we suggest installation of the optional photovoltaic solar panel Fig 3 PVT Remote G...

Страница 11: ...m Ion Battery Please read safety instructions Battery capacity 6 months use with 4 piezometers connected time between loggings 1 hour time between sending log files to the serv er 24 hours Capacity co...

Страница 12: ...y Medium size screw driver slot Small screw driver slot Pliers for cutting and stripping wire USB cable Portable computer with installed PVT Gateway setup software SIM card and information from your s...

Страница 13: ...ation about PIN code APN code etcetera connected to your subscription Close the small box and connect the battery Remove the protection lid from the micro USB outlet and connect your computer with ins...

Страница 14: ...a spare battery Charge the battery for 12 hours using the PVT Gate way battery charger The gateway will keep its settings for a few seconds If settings are lost by the gateway they will be restored u...

Страница 15: ...ns please declare serial number of the Gateway if sending it for service Please refer transport instructions for Lithium Ion Batteries Never send damaged Lithium batteries by air Trouble Shooting 4 3...

Страница 16: ...together with one spare battery Special rules apply when sending batteries alone without the equipment Do not send defect or damaged batteries by air Before sending the equipment please check applica...

Страница 17: ...GEOTECH PVT REMOTE GATEWAY Manual 2015 11 30 13 Notes Notes...

Страница 18: ...GEOTECH PVT REMOTE GATEWAY Manual 2015 11 30 2015 Ingenj rsfirman Geotech AB Datav gen 53 436 32 Askim SWEDEN Phone 4631289920 Fax 4631681639 www geotech eu info geotech se...

Отзывы: