ASSEMBLY
5
6. Route the power cord of the Pump Box
Assembly through the rectangular opening on the
side of the Tub Unit with the Inlet Filter downward
and facing inward.
The Power Switch is visible through the
rectangular opening. Hook the raised offset tab
on the rear of the Pump Box Assembly over the
bottom edge of the rectangular opening (Figs
4-5).
7. Check to see that the Tub drain plug is tightly
installed.
8. Place the Parts Cleaning Tray over the edges
on the walls of the tub (Fig 6).
9. Make sure the Nozzle of the Flexible Metal
“Gooseneck” Fluid Outlet Tube is facing in toward
the center of the Tub and downward.
10. The installation of the included Flow-through
Parts Cleaning Brush and hose extension is
optional. The molded fitting on the hose end
opposite the brush may be slipped into place over
the Fluid Outlet Tube Nozzle.
11. Be sure the Nozzle or Brush outlet is facing in
toward the center of the Tub and downward.
12. Fill unit with suitable, water-based degreasing
solution suffi ciently to cover the entire Inlet Filter
(approx.12 gallons). Important Note: Follow
degreasing solution mixing, usage and safety
label instructions carefully before using.
13. Plug power cord into an approved, grounded
and GFI equipped Outlet.
14. Turn Power Switch to the “On” position. The
Parts Washer is now ready for use.
NOTE: Brush & Rubber Hose are OPTIONAL
parts only.