![Geokon 6300 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/geokon/6300/6300_instruction-manual_2214576020.webp)
14
APPENDIX A. SPECIFICATIONS
A.1 Vibrating Wire Tilt Sensor
Model:
6300
Range:¹
±
10°
Resolution:²
8 arc seconds
Accuracy:³
±8 arc seconds
Linearity:
4
±0.3% FSR
Thermal Zero Shift:
±
4 arc seconds/
°
C
Operating
Temperature
-40 to +80° C
-40 to 175° F
Operating Frequency:
1400-3500 Hz
Coil Resistance:
180
Ω
Diameter:
1.250", 32 mm
Length:
7.375", 187 mm
Weight:
1.5 lbs., 0.7 kg.
Materials:
304 Stainless Steel
Electrical Cable:
Two twisted pair (four conductor) 22 AWG
Foil shield, PVC jacket, nominal OD=6.3 mm (0.250")
Table 1 - Model 6300 Tilt Sensor Specifications
Notes:
¹ Consult the factory for other ranges.
² Depends on readout equipment. With averaging techniques, it is possible to achieve one arc
second
³ Derived using 2
nd
order polynomial.
4
The output from the sensor is proportional to the sine of the angle of tilt
A.2 Thermistor (see Appendix B also)
Range: -80 to +150 °C
Accuracy: ±0.5 °C
Содержание 6300
Страница 2: ......
Страница 4: ......
Страница 24: ...18 APPENDIX E TYPICAL CALIBRATION REPORT Figure 11 Sample Model 6300 Calibration Report ...