![Geokon 4500-9-HDF1 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/geokon/4500-9-hdf1/4500-9-hdf1_instruction-manual_2214508012.webp)
6
| SPLICING PREP | GEOKON
5.
Remove the mylar wrapping to expose the wire leads.
6.
Strip the insulation back approximately 12 mm (½ inch) on the red & black
gauge wires and on the green & white thermistor wires.
Note:
Do not connect the fitting nut to the connector adapter until you after you
have finished splicing the wire leads. Refer to Section 2 for more information.
For instructions on making the splice, see Section 2.
1.2
FIXED END PREPARATION
1.
Unscrew and remove the cable fitting nut from the fixed end of the tube.
2.
Slide the black 02-500PEI armored cable through outer end of the Kellems
grip and and through the fitting nut.
Note:
Compress the Kellems grip lengthwise to aid in sliding the cable.
Gauge
Thermistor
Thermistor
Gauge
Shield
Connector Adapter
Fitting Nut
Grommet
Kellems grip
Kellems grip
Fitting Nut
Armored Cable