3
2.1.2 Mounting the Crackmeter
1)
Position the crackmeter so that it spans across the crack, using the rebar lengths mark
the position of holes that need to be drilled.
2)
Drill two, 5/8 inch to 3/4 inch boreholes, to the depth necessary to leave the crack
meter at the desire height above the surface.
3)
Fill both holes with quick-setting grout and push the rebars into the grout-filled holes.
4)
Wait for the grout to set up.
5)
Remove the cap screws holding the Delrin spacer block(s) in place, then use a
screwdriver or other appropriate tool to remove the spacers from the crackmeter.
6)
Initial readings
must be carefully taken and accurately recorded
at the time of
installation. These readings serve as a reference point against which all subsequent
readings will be compared. To take a reading, follow the instructions in Section 3.